Product Description
DRUCK UPS III-IS Intrinsically Safe Loop Calibrator
DRUCK UPS-III (Non-IS) is the Un-Certified ATEX Version of the DRUCK UPS-III-IS Intrinsically Safe Loop Calibrator
DRUCK UPS III-IS Intrinsically Safe Loop Calibrator mA-V Certified Safe
The DRUCK UPS III-IS Intrinsically Safe Loop Calibrator is an mA-Volt calibrator that has been designed for, tested and certified to meet the rigorous conformity requirements of EN 61010, EN 61326:1997 + A1 (1998) + A2 (2001) + A3(2003), CE marked, Certified for use in hazardous areas with volatile gaseous atmospheres, ATEX: II 2G Ex ib IIC T4 (-10°C<Ta<+40°C) Certificate number BASEEFA 06ATEX0224X, IEC: Ex ib IIC T4 (-10°C<Ta<+40°C) Certificate number IECEx BAS 06.0053X.
DRUCK UPS III IS Intrinsically Safe Loop Calibrator Highlights
- ATEX/IEC intrinsically safe
- Measure or source 0 to 24 mA
- Accuracy 0.015% of reading
- Dual mA and % readout, linear or flow
- Step, span check, valve check, ramp
- 50 VDC measurement and continuity
- HART® compatible
- Dimensions (w x h x d) – 3.5 in x 5.5 in x 1.7 in (90 mm x 140 mm x 42 mm)
- Weight – 16.2 oz (460 g) including batteries and leather case
- Display – Graphic LCD, 1.2 in x 2.1 in (31 mm x 54 mm)
Druck UPS III IS Measure or Source
♦ 0 to 24 mA, An internal loop supply is available in both measure and source modes, essential during plant shutdowns.
Druck UPS III IS Accuracy 0.015% of Reading
♦ This includes 12 month stability and temperature effects The UPS III IS can maintain a 4:1 calibration ratio with the latest instrumentation and is typically 10 to 40 times more accurate than a Digital Multi-Meter (DMM).
DRUCK UPS III-IS Intrinsically Safe Loop Calibrator ~ Simultaneous % Readout
♦ Displays mA and the percentage value of 4 to 20 mA or 0 to 20 mA. The UPS III IS also converts mA readings to % flow. This is not possible with many loop calibrators.
Druck UPS III IS Supplied As Standard
♦ The UPS III IS is supplied as standard with leather case and carry strap, a certificate of calibration, user guide, test leads, and a set of alkaline batteries.
DRUCK UPS III-IS Intrinsically Safe Loop Calibrator ~ Auto Step and Ramp
♦ Outputs have adjustable rates (1 to 599 seconds) for single-handed loop testing, valve set-up and slew rate checks
Druck UPS III IS “Fast Set” Output
♦ Allows values to be set to within 0.001 mA using the arrow keys. Holding a key quickly ramps the output to the next value. The system is ideal for alarm trip tests.
Druck UPS III IS Step, Span Check and Value Check
♦ Step quickly through linearity tests and zero/span adjustments. In valve mode, seating can be checked and the actuator set.
Druck UPS III IS 50 VDC Measurement
♦ For loop diagnostics and maintenance of voltage output instruments