944i |
V4 |
V63 |
V61 |
V60 |
930i |
V5 |
Functions |
AC & DC Hipot Insulation Resistance Ground Continuity ~ Low AC Resistance |
AC & DC Hipot Insulation Resistance Ground Bond |
AC & DC Hipot, Insulation Resistance Ground Continuity~ Low AC Resistance |
AC & DC Hipot, Ground Continuity ~ Low AC Resistance
|
AC Hipot, Ground Continuity |
Ground Bond (GB) |
AC & DC Hipot, Insulation Resistance, G B & HV Scanner |
AC Hipot Dielectric Breakdown |
5KV RMS Std,
8KV optional
35mA Max
10nano A Res.
40-100Hz |
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz |
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz |
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz |
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz |
- |
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz |
DC Hipot Arc Detection |
5KVDC Std,
7 & 10KVDC
option
35 mA max
1nano A resolution |
6KVDC, megger
10 mA max
10μA Resolution |
6KV,
10 mA max10μA Resolution |
6KVDC,
10 mA max
10μA Resolution |
- |
- |
6KVDC,
10 mA max
10μA Resolution |
IR
(Insulation
Resistance) Voltage Withstand |
100GΩ
100-5000V std
10-99V optional
Multi-mode |
10GΩ max
50, 100, 500, 1000VDC
Multi-mode |
10GΩ max
50, 100, 500, 1000VDC
Multi-mode |
- |
- |
- |
10GΩ max
50, 100, 500, 1000VDC
Multi-mode |
Ground Bond &
Ground Continuity ~ AC Low Resistance
|
Ground Continuity, 50mA
1mΩ to 8Ω std
1mΩ to 1kΩ opt. |
Ground Bond
3-42A, 4-wInsulation Resistance
100μΩ res. |
Ground Continuity
100mA 2-w Insulation Resistance
10mΩ to 1.5Ω |
Ground Continuity
100mA 2-w nsulation Resistance
10mΩ to 1.5Ω |
Ground Continuity
100mA 2-wInsulation Resistance
10mΩ to 1.5Ω |
Ground Bond
3-30A, 4-w Insulation Resistance
40A optional |
Ground Bond
3-42A, 4-wInsulation Resistance
e
100μΩ res. |
Test
Memory |
40 Positions
200 steps total |
10 positions
Up to 16 steps ea |
10 positions
Up to 16 steps ea |
10 positions
Up to 16 steps ea |
10 positions
Up to 16 steps ea |
10 Position |
10 positions
Up to 16 steps ea |
Arc Detection |
Selectable
1μS, 10μS, 30μS |
Selectable
1-40mA |
Selectable
1-40mA |
Selectable
1-40mA |
Selectable
1-40mA |
- |
Selectable
1-40mA |
Safety fault Interrupt |
Optional |
Std |
Std |
Std |
Std |
- |
Optional |
Special
Features |
Same as others,
Plus:
Ramp Down, Dual Ramp & dwell limits |
Digital setup,
Displayed results,
Auto cal
Line & load reg |
Digital setup,
Displayed results,
Auto cal
Line & load reg |
Digital setup,
Displayed results,
Auto cal
Line & load reg |
Digital setup,
Displayed results,
Auto cal
Line & load reg |
Digital setup,
Displayed results,
Auto cal
Line & load reg |
Digital setup,
Displayed results,
Auto cal
Line & load reg |
Interfaces |
RS232, PLC, GPIB IEEE-488
Printer port optional |
RS232, PLC & Scanner control std
GPIB IEEE-488 optional |
RS232, PLC & Scanner control std
GPIB IEEE-488 optional |
RS232, PLC & Scanner control std
GPIB IEEE-488 optional |
RS232, PLC & Scanner control std
GPIB IEEE-488 optional |
RS232 & VICL
Standard |
RS232, PLC & Scanner control std
GPIB IEEE-488 optional |
Failure indications |
Audible & Visual |
Audible & Visual |
Audible & Visual |
Audible & Visual |
Audible & Visual |
Audible & Visual |
Audible & Visual |
Rackmount/
Rear Output |
Optional
Optional |
Optional
Standard |
Optional
Optional |
Optional
Optional |
Optional
Optional |
Optional
Standard |
Standard
Standard |
| Down Load Data Sheet |
|
|
|
|
|
|
|
| Budgetary Price |
$4790.00 |
$3295.00 |
$2085.00 |
$1585.00 |
$1295.00 |
$2590.00 |
$4990.00 |