SPECIFICATIONS PPE-3323 Programmable Linear DC Power Supply (0~+32V)/3A, (0~-32V)/3A, 5V/3.3A |
OUTPUT |
Voltage |
0~+32V, 0~-32V, 3.3V/5V Fixed |
Current |
0~+3A, 0~-3A, 3A Fixed |
OVP |
0~+33V, 0~-33V |
LOAD REGULATION |
Voltage |
< 6mV |
Current |
< 3mA |
LINE REGULATION |
Voltage |
< 3mV |
Current |
< 3mA |
RESOLUTION |
Voltage |
10mV ( 20mV rating voltage > 36V ) |
Current |
1mA ( 2mA rating current >3.5A ) |
OVP |
10mV( 20mV rating voltage > 36V ) |
PROGRAM ACCURACY (25±5° C) |
Voltage |
< 0.05% + 25mV ( + 50mV rating voltage > 36 V ) |
Current |
< 0.2% + 10mA |
OVP |
< 2% + 0.6V |
RIPPLE & NOISE (20Hz ~ 20MHz) |
Voltage |
Ripple 1mVrms / 3mVp-p
Noise 2mVrms / 30mVp-p |
Current |
< 3mA rms ( < 5mA rms rating current > 3.5A ) |
TEMPERATURE (0~40° C ) COEFFICIENT |
Voltage |
< 100ppm + 3mV |
Current |
< 150ppm + 3mA |
READBACK RESOLUTION |
Voltage |
10mV ( 20mV rating voltage > 36V ) |
Current |
1mA ( 2mA rating current > 3.5A ) |
READBACK ACCURACY (25±5° C) |
Voltage |
< 0.05% + 25mV ( + 50mV rating voltage > 36V ) |
Current |
< 0.2% + 10mA |
RESPONSE TIME |
Voltage Up(10%~90%) |
< 100mS |
Voltage Down(90%~10%) |
< 100mS |
READBACK TEMPERATURE COEFFICIENT |
Voltage |
< 100ppm + 10mV ( + 20mV rating voltage > 36V ) |
Current |
< 150ppm + 10mA |
DRIFT |
Voltage |
< 0.03% + 6mV |
Current |
< 0.1% + 6mA |
TRACK OPERATION |
Tracking Error |
< 0.1% + 50mV |
Series Regulation |
< 50mV |
MEMORY |
|
Store / Recall 0 ~ 49 set |
TIMER |
Setting time |
1 sec ~ 99 min ( Max 99 min x 49 ) |
Resolution |
1 sec |
Function |
for output working loop ( Auto Step Running) |
INTERFACE |
|
RS-232 |
POWER SOURCE |
|
|
AC100V/120V/220V/240V±10%, 50/60Hz |
ACCESSORIES |
|
User manual x 1
Power cord x 1
Test lead GTL-105 x 3 |
DIMENSIONS & WEIGHT |
|
|
255(W) x 145(H) x 346(D)mm
Approx. 10 kg |