DC OUTPUT |
|
CH1, CH2 |
CH3 |
|
| Voltage |
|
| Current |
|
| Tracking Series Voltage |
|
| Tracking Parallel Current |
|
CONSTANT VOLTAGE OPERATION (CH1, CH2) |
| Line Regulation |
< 0.01% + 3mV |
| Load Regulation |
< 0.01% + 3mV (rating current <3A)
< 0.02% + 5mV (rating current >3A) |
| Ripple & Noise |
< 1mVrms 5Hz ~ 1MHz |
| Recovery Time |
< 100μS ( 50% Load change, Minimum load 0.5A ) |
CONSTANT CURRENT OPERATION (CH1, CH2) |
| Line Regulation |
< 0.2% + 3mA |
| Load Regulation |
< 0.2% + 3mA |
| Ripple Current |
< 3mArms |
TRACKING OPERATION (CH1, CH2) |
| Tracking Error |
< 0.5% + 10mV of CH1 |
| Series Regulation |
< 300mV |
| Load Regulation |
< 0.01% + 3mV |
| Ripple & Noise |
< 2mVrms 5Hz ~ 1MHz |
CH3 OPERATION |
| CH3 Voltage |
5V Fixed |
| Line Regulation |
< 5mV |
| Load Regulation |
< 15mV |
| Ripple & Noise |
< 2mVrms 5Hz ~ 1MHz |
| Current Output |
3A |
METER |
| Digital |
3 Digits 0.5" LED Display
Out On Accuracy± ( 0.5% of rdg + 2 digits )
Out On Accuracy± ( 0.5% of rdg + 8 digits ) |
INSULATION |
| Chassis and Terminal |
> DC 500V / 20MΩ |
| Chassis and AC Cord |
> DC 500V / 30MΩ |
| POWER SOURCE |
|
|
|
AC 100V/120V/220V ±10%, 230V(+10% ~ -6%), 50/60Hz |
ACCESSORIES |
|
User manual x 1
Power cord x 1
Test lead GTL-104 x 2, GTL-105 x 1
European test lead GTL-203 x 1, GTL-204 x 2
Sense lead GTL-201A x1 |
| DIMENSIONS & WEIGHT |
|
255(W) x 145(H) x 265(D)mm, Approx. 7kg |