 GW Instek GOS Analog Oscilloscopes  |
Model |
GW Instek Oscilloscopes (Analog-Real Time) |
specs |
man |
List |
Price |
GW Instek 10MHz to 50 MHz Oscilloscopes |
| Instek GOS-310 |
Oscilloscope,10MHz Analog Real Time Scope ~ Discontinued See GOS-620 |
|
|
Discontinued |
|
| Instek GOS-6030 |
30Mhz Analog Oscilloscope, Cursor |
|
|
Obsolete |
|
| Instek GOS-6031 |
30Mhz Analog Oscilloscope, Cursor, Recall & Counter |
|
|
Obsolete |
|
| Instek GOS-6050 |
50Mhz Analog Oscilloscope, Cursor |
|
|
Obsolete |
|
| Instek GOS-6051 |
50Mhz Analog Oscilloscope, Cursor, Recall & Counter |
|
|
Obsolete |
|
| Instek GOS-620 |
Analog Oscilliscope - 20MHz |
|
|
$420.00 |
|
| Instek GOS-620FG |
Analog Oscilliscope - 20MHz with Function Generator |
|
|
$530.00 |
|
| Instek GOS-622G |
Analog Oscilliscope - 20MHz |
|
|
$470.00 |
|
| GOS-635G |
Analog Oscilliscope - 35MHz |
|
|
$535.00 |
|
| Instek GOS-653G |
Analog Oscilliscope - 50MHz |
|
|
$810.00 |
|
|
Please-mailATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.

|
|
To assist our customers in satisfying ISO-9001:2000, section 8.2, certified monitor and measurement calibration requirements, ATEQUIP.com can supply for all of the GW INSTEK products, certified NIST traceable calibration certificates from an ANSI/NCSL Z540-1-1994 compliant-accredited/ ISO 17025 accredited calibration laboratory. Please contact us directly for information on your specific test equipment interest. |
GW Instek 100 MHz Oscilloscopes |
| Instek GOS-6103 |
Analog Oscilliscope - 100MHz, cursor readout |
|
|
$1320.00 |
|
| Instek GOS-6103C |
Analog Oscilliscope - 100MHz with counter |
|
|
$1395.00 |
|
| Instek GOS-6112 |
Analog Oscilliscope - 100MHz, cursor readout, no memory |
|
|
$1175.00 |
|
| Instek GOS-6200 |
Analog Oscilliscope - 200MHz, cursor readout |
|
|
$2025.00 |
|
| |
Instek GOS-6200
MSRP $1950 |
Instek GOS-622G
MSRP $460 |
|
FEATURES GW Instek GOS-6200 Oscilloscope |
200MHz Bandwidth, Dual Channel, Delayed Sweep
Auto Set
Built-in 6 Digits Universal Counter
Cursor Readout with 7 Measurements
10 Sets Memory for Front Panel Setting Save & Recall
TV-Line Selection (NTSC, PAL, SECAM)
Panel Setup Lock of Digital-Control Functions
Buzzer Alarm
LED Indicators
Trigger Signal Output
Z-axis Modulation Input
SMD Technology, High Stability and Reliability
|
|
FEATURES GW Instek GOS-622G Oscilloscope |
20MHz Bandwidth, Dual Channel
High Sensitivity 1mV/div
TV Synchronization
Z-axis Input
ALT Triggering Function
Hold Off Function
CH1 Output
|
Instek GOS-6200 200MHz Oscilloscope
SPECIFICATIONS |
|
CRT
|
Type
|
6-inch rectangular type with internal Graticule;
0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
|
|
Phosphor |
P31 |
|
Accelerating Potential |
14 kV approx. |
|
Illumination |
Continuously adjustable |
|
Z-axis input |
Coupling : DC |
|
Sensitivity : 5V or more |
|
Maximum input voltage : 30V (DC+AC peak) at 1kHz or less |
|
Bandwidth : DC ~ 5MHz |
|
VERTICAL SYSTEM |
Sensitivity |
2mV ~ 5V/DIV,11 step in 1-2-5 sequence |
|
Sensitivity Accuracy |
< 3% (5 DIV at the center of display) |
|
Vernier Vertical Sensitivity |
Continuously variable to 1/2.5 or less panel-indicate value |
|
Bandwidth(-3dB) |
DC ~ 200MHz (2mV/DIV : DC ~ 20MHz) |
|
Rise Time |
1.75nS (2mV/DIV : 17.5 nsec) |
|
Signal Delay |
Leading edge can be monitored |
|
Max. Input Voltage |
400V (DC+AC peak) at 1kHz or less |
|
Input Coupling |
AC, DC, GND |
|
Input Impedance |
1MΩ+2%// approx. 25pF |
|
Vertical Mode |
CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV. |
|
Bandwidth Limited |
20MHz |
|
Common-Mode Rejection Ratio |
50 :1 or better at 50kHz |
|
Dynamic Range |
8 div at 100MHz;5 div at 200MHz |
|
HORIZONTAL SYSTEM |
Horizontal Modes |
MAIN(A), ALT, DELAY(B) |
|
A(main)Sweep Time |
20nS ~ 0.5S / DIV, continuously variable (UNCAL) |
|
B(delay)Sweep Time |
20nS ~ 50mS/DIV |
|
Accuracy |
+ 3% (+ 5% at x 10 MAG) |
|
Sweep Magnification |
x 10 (maximum sweep time 2nS / DIV) |
|
Hold Off Time |
Variable |
|
Delay Time |
1µS ~ 5S |
|
Delay Jitter |
Better than 1:20000 |
|
Alternate Separation |
Variable |
|
TRIGGER |
Trigger Modes |
AUTO, NORM, TV |
|
Trigger Source |
CH1, CH2, LINE, EXT, EXT/10 |
|
Trigger Coupling |
AC, DC, HFR, LFR, NR |
|
Trigger Slope |
"+" or "-" polarity or TV sync polarity |
|
Trigger Sensitivity
Mode |
Frequency |
INT |
EXT |
EXT/10 |
AUTO |
10Hz~20MHz |
0.35 DIV |
50 mV |
500 mV |
20MHz~200MHz |
1.5 DIV |
150 mV |
1.5 V |
NORM |
DC~20MHz |
0.35 DIV |
50 mV |
500 mV |
20MHz~200MHz |
1.5 DIV |
150 mV |
1.5 V |
TV |
sync signal |
1 DIV |
200 mVpp |
2 Vpp |
|
|
Trigger Level Range |
INT :±4DIV or more; EXT :±0.4V or more;EXT/10 :±4V or more |
|
TV Triggering |
Mode : TV-V, TV-H, TV-LINE |
|
TV-Line Selection
Standard |
Filed 1 |
Filed 2 |
NTSC (525H) |
1H~263H |
1H~262H |
PAL (625H) |
1H~313H |
1H~312H |
SECAM (625H) |
1H~313H |
1H~312H |
|
|
Max. External Input Voltage |
400V (DC+AC peak) at 1kHz |
External Input Impedance |
1MΩ + 5%, // approx. 25pF |
X-Y OPERATION |
Mode |
X-axis : selectable CH1, EXT, EXT/10 |
Y-axis : selectable CH1, CH2, CH1 and CH2 |
Sensitivity Accuracy |
2mV ~ 5V / DIV ±3%; EXT : 0.1V / DIV±5%; EXT / 10 :1V / DIV±5% |
X-axis Bandwidth |
DC ~ 500kHz (-3dB) |
Phase Error |
3º or less from DC ~ 50kHz |
OUTPUT SIGNAL |
Trigger Signal Output |
Voltage : approx. 25mV/DIV into 50Ω |
Frequency response : DC ~ 10MHz |
Calibrator Output |
1kHz Square wave, 2Vpp±2% |
Cursor Readout Function |
Qwer980-J |
ΔV,ΔV%,ΔVdB,ΔT,1/ΔT,ΔT%,Δθ |
Cursor Resolution |
1 / 100 DIV |
Effective Cursor Range |
Vertical : ±3DIV ; Horizontal : ±4DIV |
Panel Setting Display |
Vertical : V/DIV(CH1,CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND |
Horizontal : S/DIV(MTB,DTB), UNCAL, x 10MAG, delay time, HO |
Trigger : source, coupling, slope, level, TV-V, TV-H |
Others : X-Y, lock, save/recall MEM 0-9 |
AUTO MEASUREMENTFUNCTION |
Parameter Function |
FREQ, PERIOD, ±WIDTH, ±DUTY ( + or - polarity selected by trigger slope) |
Display Digits |
Max. 6-digits, decimal |
Frequency Range |
50Hz ~ 200MHz |
Accuracy |
1kHz ~ 200MHz : +0.01%;50Hz ~ 1kHz : +0.05% |
Measuring Sensitivity |
>2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources) |
SPECIAL FUNCTION |
Auto Set |
Input Channel : CH1, CH2;Frequency Response 50Hz~50MHz |
Panel Setting Save & Recall |
10 sets |
Panel Setups Lock |
Provided |
POWER SOURCE |
AC 100V / 120V / 230V + 10%, 50 / 60Hz |
ACCESSORIES |
Power cord x 1;
Instruction manual x 1;
Probes(10:1/1:1) x 2 |
DIMENSIONS |
310(W) x 150(H) x 470(D) mm; |
WEIGHT |
Approx. 9kg |
|
|
|