GW Instek GLA Series Logic Analyzers

 

GW Instek GLA- 1132 Logic Analyzer FEATURES

  16-32 Input Channels
Time Analysis : Up to 200MHz Internal Sampling Rate
  State Analysis : Up to 100MHz External Input Clock
  Memory Depth : Up to 2Mbits/1Mbits (Half/Full Channels)
Advanced Trigger : Count, Page, Time Delay and Clock Event Delay
Data Compression : Up to 255 Times Data Capture
Enable Qualifier : High/Low Level Enable and Enable Delay Function
Signal Analyzer : I²C, RS-232C Protocol Analyzer and Signal Statistics
File Export : Signal Data, Operation Setting and Display Image
Manual Trigger Start Button
  High-Speed Communication : USB 2.0 (1.1 Compatible)

USB Powered, Without External AC Power

Compact Size with Full Functionality
The GW INSTEK GLA-1000 Series is a palm-size PC based logic analyzer featuring functionality matching that of a desktop device. The maximum 32 channels, 1Mbits of data memory with powerful features of GLA-1000 Series provide Digital Engineers & Professionals alike with a tool that easily deciphers today's complex digital system analysis. All the operations of GLA-1000 Series are accomplished in the environment of Window TM based PC software that provides a user-familiar with GUI a large screen display facilitating the complex measurement analysis of digital systems.

High-Speed Signal Acquisition and Measurements
With 200MHz internal sampling rate, the timing analysis of GLA-1000 Series conforms to today's cutting edge digital technology. The 100MHz external sampling rate gives user high confidence in performing table and synchronized state analysis. The maximum 1Mbits of data memory per channel, enhanced by up to x 255 data-loss-less compression, enables longer data acquisition and deeper data analysis. The channel grouping could be done randomly based on the user-defined configuration, which provides flexible channel arrangements for sophisticated digital measurements.

Advanced Trigger Functions
The trigger setting may be done either from a trigger selection soft key in front of each channel display for individual channel setting or through a dialog window for pre-defined Bus pattern settings. The selection of trigger conditions include high, low, rising edge, falling edge, either edge and don't-care for all channels or a Binary, Decimal or Hexadecimal code of a pre-defined Bus. The user-selectable threshold, in TTL, CMOS, ECL and user-defined voltage (-6.0V~+6.0V), allows quick adoption of measurements on a multi-voltage digital system. Like a modern DSO , GLA-1000 Series features advanced trigger functions , including time delay trigger, clock event delay trigger, page delay trigger and Post/Pre trigger display. The unique feature "Enable Qualifier" picks up only the portions of data that match the user pre-defined condition after the signal being triggered. This function effectively reduces the redundant data and collects as much as possible the useful data sections within the limited memory. Three control signal output terminals, Start, Trigger & End, are provided to facilitate the control over external devices. When GLA-1000 Series triggers on a signal, its trigger output signal could activate a DSO to get a
synchronized-real-time waveform for the cross-reference of digital data and analog signal waveform. This is a typical example among all the applications
of control signal outputs.

Powerful Data Analysis Capability
A data-search dialogue window assists in finding the user-defined data from the chunky data stream acquired after triggering. A bar cursor automatically
locates the found data pattern and puts it on to the screen center. The additional bar(s) may be used to indicate time or clock event between two data patterns of interest. A statistics feature is provided to calculate the number count of a user-defined data pattern that shows up within the overall acquired data stream or to calculate the number count of a user defined high-low status of the data section that shows up in a channel. GLA-1000 Series also offers a tool to perform the analysis of serial bus protocol. This feature supports the most popular standards, RS-232C & IC.

User-friendly Operation
All the settings & operations of GLA-1000 Series are done under the Windows TM environment, which offers the customizable keyboard shortcuts and the toolbar icons that could significantly shorten the learning curve of the first-time users.
The horizontal scale of the display is selectable between time and sampling clock and the data waveform is selectable between Ramp & Square to accommodate various application demands. The screen background and data waveforms are all
color-definable to ease the observation of display Information. A default color configuration is provided for easy getting-back to the standard color setting once needed.

Flexible File Export Functions
The whole, or a user-defined clip of screen image, captured data and setting of GLA-1000 Series may be saved as various types of files into PC for further data analysis, reporting, and other applications. The USB 2.0 communication between GLA-1000 Series and the PC guarantees the secured data transfer at the maximum speed while providing GLA-1000 Series with a power source.

 

Please-mailATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.

To assist our customers in satisfying ISO-9001:2000, section 8.2, certified monitor and measurement calibration requirements, ATEQUIP.com can supply for all of the GW INSTEK products, certified NIST traceable calibration certificates from an ANSI/NCSL Z540-1-1994 compliant-accredited/ ISO 17025 accredited calibration laboratory. Please contact us directly for information on your specific test equipment interest.