cart
atequip logo
Instek Gfc series frequency counters

Main Menu
 
New Product
Product Catalog
 GW Instek Gfc series frequency counters 
Model GW instek frequency counters

Data

Man List Price
GFC-8270H FrequencyCounter - 2.7 GHz
pdf
pdf
$395.00
$356 Buy Now
GFC-8131H Frequency Counter~1.3GHz
pdf
pdf
$305.00
$274.10 Buy Now
GFC-8010H Frequency Counter~120MHz
pdf
pdf
$195.00
$175.50 Buy Now
Please-mail ATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.

GW Instek GFC-8270H (2.7GHz)

MSRP $395
Instek GFC-8270H Features

Frequency, Period measurements

Microprocessor controlled intelligent counter

High resolution at both high and low frequency

0.01Hz ~ 2.7GHz frequency range

10mVrms High sensitivity

100nHz resolution for 1Hz

Self diagnosis routine

Variable Trigger Level control

Display hold function

To assist our customers in satisfying ISO-9001:2000, section 8.2, certified monitor and measurement calibration requirements, ATEQUIP.com can supply for all of the GW INSTEK products, certified NIST traceable calibration certificates from an ANSI/NCSL Z540-1-1994 compliant-accredited/ ISO 17025 accredited calibration laboratory. Please contact us directly for information on your specific test equipment interest.

SPECIFICATIONS GW Instek  GFC-8270H~2.7GHz Frequency Counter


Display


8 digits with Hz, KHz, MHz, GHz, S, mS, µS, nS and overflow

Gate Time

Continuously vary from 10mS to 10S, or 1 period of input depending on whichever is greater

Accuracy

+(Resolution +Time base error)

Channel A

Range

DC coupled 0.01Hz ~ 120MHz;AC coupled 30Hz ~ 120MHz

Sensitivity

10mVrms typical; 50mVrms max

Coupling

AC or DC Switchable

Filter

Low pass, Switchable in or out for channel A.-3dB point of nominally 100kHz

      Impedance

1MΩ//40pF

      Attenuator

x 20dB

      Trigger Level Adjustment

-2.5 VDC to +2.5 VDC

      Resolution

The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively.
At least 7,6,5 digits are display for 1S, 100mS, 10mS gate time respectively

Period Range

8nS to 100S at least 7 digits displayed for per second of gate time

Channel B

Range

50MHz to 2.7GHz

      Sensitivity

<50mVrms (10mVrms typical)

      Coupling

AC only

Time Base

Aging Rate

1 ppm, per Month

Temperature

5 ppm 23°C + 5°C

General  

Line Variation

+0.005 ppm for +10% variation

Power Source

AC 100V/120V/220V/240V ±10%, 50/60Hz

Accessories

Instruction manual × 1,
Power cord × 1,
GTL-101
× 1

Dimensions & Weight 230(W) × 95(H) × 280(D) mm, Approx. 2.2kg

    

   SPECIFICATIONS Instek GFC-8131H 1.3GHZ Frequency Counter


Display


8 digits with Hz, kHz, MHz, GHz, S, mS, µS, nS and overflow

Gate Time

Continuously vary from 10mS to 10S, or 1 period of input depending on whichever is greater

Accuracy

+(Resolution +Time base error)

Channel A

Range

DC coupled 0.01Hz ~ 120MHz;AC coupled 30Hz ~ 120MHz

Sensitivity

10mVrms typical; 50mVrms max

Coupling

AC or DC Switchable

Filter

Low pass, Switchable in or out for channel A.-3dB point of nominally 100kHz

      Impedance

1MΩ//40pF

      Attenuator

x 20dB

      Trigger Level Adjustment

-2.5 VDC to +2.5 VDC

      Resolution

The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively.
At least 7,6,5 digits are display for 1S, 100mS, 10mS gate time respectively

Period Range

8nS to 100S at least 7 digits displayed for per second of gate time

Channel B

Range

50MHz to 1.3GHz

      Sensitivity

<40mVrms (10mVrms typical)

      Coupling

AC only

Time Base

Aging Rate

1 ppm, per Month

Temperature

5 ppm 23°C + 5°C

Line Variation

+0.005 ppm for +10% variation

General

Power Source

AC 100V/120V/220V/240V ±10%, 50/60Hz

Accessories

Instruction manual × 1,
Power cord × 1,
GTL-101
× 1

  Dimensions & Weight 230(W) × 95(H) × 280(D) mm, Approx. 2.2kg
 

     SPECIFICATIONS Instek GFC-8010H120MHz Counter


Display

8 digits with Hz, kHz, MHz, GHz, S, mS, µS, nS and overflow

Gate Time

0.1S, 1S, 10S switch selectable

Accuracy

+(1 digit + Time Base accuracy)

Input

Sensitivity

10Hz ~ 60MHz < 20mVrms;
60MHz ~ 100MHz < 30mVrms;
100MHz ~ 120MHz < 40mVrms

Impedance

1MΩ//35pF

Coupling System

AC Coupling

Max Input Voltage

150Vrms

Time Base

Oscillation Frequency

10MHz

Aging Rate

+1 ppm per month

Temp. Stability

25°C + 5°C:+5 ppm

Resolution

The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively.

General

Power Source

AC 100V/120V/220V/230V ±10%, 50/60Hz

Accessories

Instruction manual × 1,
Power cord × 1,
Test Lead GTL-101 × 1

Dimensions & Weight

230(W) × 95(H) × 280(D) mm, Approx. 1.7kg