|
|
|
FLUKE Ti20 Thermal Imagers | Ti20 Thermal Imaging Camera |
|
Fluke TI20 Thermal Imager

|
Fluke Ti20 Thermal Imaging Camera ~ The ultimate tool for troubleshooting and maintenance
The Fluke Ti20 Thermal Imaging Camera is the perfect tool to add to your problem solving arsenal. Built for tough work environments, this high-performance, fully radiometric infrared camera is ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
Fluke Ti20 Features IR-Fusion® Technology
See things both ways—Thermal imaging- infrared and visual (visible light) images fused together communicating critical information faster and easier—traditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and fuses it together taking the mystery out of IR image analysis. IR-Fusion is standard on the Fluke Ti20 Thermal Imaging Camera.
|
|
|
Fluke Ti20 ~ The Perfect Thermal Imagers for Every Day Trouble Shooting
The Fluke Ti20 Thermal Imaging Camera is the perfect tools to add to your problem solving arsenal. Built for tough work environments, these high-performance, fully radiometric imagers are ideal for troubleshooting electrical installations, electro-mechanical equipment, process instrumentation, HVAC equipment and others.
Enhanced problem detection and analysis capabilities with IR-Fusion@Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal or Automatic (auto) Blend visual and thermal images.

Ironbow |

Blue-Red |

High Contrast |

Amber |

Hot Metal |

Gray |
Palette-Color representation of the temperatures (temperature scale) in a displayed image. Certain color palettes meet personal preferences or optimize the image for different applications and/or problems. An example of the different palettes appear to the right.
Sensor Size-Similar to digital cameras the sensor size describes the amount of displayed points per image of a thermal imager. A sensor size of 160 x 120 captures and displays more than 19,CDO measurement points with each measurement. This is more than sufficient for almost all industrial and electrical applications. If the imager is fully radiometric then it also truly measures and stores all captured points with the image.
Field of view (FOV)-Indicates what the thermal imager sees or measures at a given moment. The combination of the Field Of View specification and the distance to the measured object determines which surface or part of an object will be measured as a total. A thermal imager with a FOV of 23° x }70 (20 m), F=0.8 lens)
can detect an object that is 6 m (20 ft) wide by 4.5 m(15 ft) high. This same imager can infer a temperature measurement of a smaller section within that object of 3.8 cm X 3.8 cm (1.5 in x 1.5 in). A FOV calculator on www.fluke.com/FOV helps you calculate the measurement surface at various distances to the object.
Thermal sensitivity-Indicates what the smallest temperature difference is which can
be measured/displayed in an image. It basically is the maximum resolution of the image and is referred to as NETD (noise equivalent temperature difference). A NETD of 200 mK is more than adequate for most industrial and electrical applications.
Emissive adjustment-All surfaces emit infrared energy or heat. The level of emission varies much per surface and is described
with the term emissive. Painted coatings
and materials usually have a high emissive while polished aluminum has a low emissivity. Visit www.fluke.com/emissivity for a table
with emissivities for different materials. If you perform qualitative inspections with the imager (most applications) then emissivity does not have to be adjusted. To measure the temperature of a material accurately it will be necessary to adjust for the material's emissivity in specific applications.
Span-The set of temperature values that can be measured within a preset range. Adjusting the span allows you to see more subtle temperature gradients (or contrast) in a captured image. When the span is optimized the imager shows 256 different shades of color in an image.

|
| Fluke Ti20 Thermal Imaging Camera Highlights |
- Thermal Detector uncooled focal plane array
- NETD 200 mK
- Temperature Range -10 to 350 °C (14 to 662 °F)
- Accuracy +/- 2 °C or 2% (whichever greater)
- Display Large Color LCD
- Optics Field of View 20° horizontal by 15° vertical
- Target sighting Single laser (IEC & FDA Class II)
- Adjustments include: Focus 61 cm (24 in.) to infinity; Emissivity 0.10 to 1.00 in 0.01 increments; RTC Reflected Temperature Correction; Temperature Scale °C or °F; Measurement Mode Manual Level and Span Adj.; Palette Selection Grayscale, Reverse Grayscale, Rainbow, Ironbow
- Image capture 50 images stored internally
- Warranty 1 year
- Power Rechargeable battery pack
- Environmental Ambient Temperature -10 to 50 °C (14 to 122 °F)
- Relative Humidity 10 to 90% noncondensing
- Storage Temperature -25 to 70 °C (-13 to 158 °F)
- and reporting software
- Two-year warranty
|
Fluke Ti20 Thermal imaging Camera w/ 20 mm lens order.
Includes:
- AC power supply/battery charger (including mains adapters)
- SD memory card
- SD card reader (USB) for downloading images into your computer
- SmartView™ software with free software upgrades for life
- Rugged hard carrying case
- Soft transport bag
- Hand strap
- Users manual
- Warranty registration card
|
|
| Detailed Specifications |
| Thermal |
Temperature measurement range (not calibrated below -10 °C) |
-10 °C to +350 °C (14 °F to + 662 °F) |
Accuracy |
±2 °C or 2 % (whichever is greater) |
| Imaging Performance |
Field of view |
FOV) 20 ° horizontal by 15 ° vertical |
Optical resolution |
(D:S) 75:1 or better |
Minimum focus distance |
Focus 61 cm (24 in) to infinity |
Target Sighting |
Single laser (meets IEC Class 2 & FDA Class II
requirements) |
Image frequency |
9 Hz refresh rate |
Detector type |
Detector Type: 128 x 96 uncooled focal plane array
NETD (Thermal Sensitivity): 200 mK
|
| Image Presentation |
Palettes |
Grayscale, reverse grayscale, rainbow, ironbow |
Measurement Mode |
Temperature Scale ºC or ºF selectable
|
Image Frame Rate |
30 Hz*, 9 Hz |
| General Specifications [Back to Top] |
Temperature |
Operating: |
0 °C to 50 °C (32 °F to 112 °F) |
Storage: |
-25 °C to +70 °C (-13 °F to 158 °F) without batteries |
Relative humidity |
10 % to 95 % non-condensing |
|
Display |
Large Color LCDLCD Backlight Bright, dim selectable |
|
Controls and Adjustments |
User selectable temperature scale (°C/°F) |
|
|
| Adjustable Emissivity |
0.10 to 1.00 in 0.01 increments |
| Reflected Background |
Adjustable Reflected Temperature
-50 ºC to 460 °C (-58 ºF to 860 ºF) |
| Storage Capacity |
50 images stored internally |
Software |
software InsideIR™ (included) full featured analysis and reporting
software (unlimited use; no per user license fees) |
Power |
Battery: |
Internal rechargeable battery pack (included)(AA) |
Battery life: |
Three to four hours continuous use (assumes 50 % brightness of LCD) |
Battery charge time |
Two hours for full charge ( using ac adapter/charger and dc car charger) |
AC Operation/Charging |
AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included. |
Dimensions (HxWxL) |
254 mm x 102 mm x 178 mm (16 in x 8 in x 12 in) |
Weight |
1.2 kg (2.65 lb)(Ship Wt. 4lbs.) |
IP Rrating |
IP5 |
Warranty |
One Year |
Calibration Cycle |
One Year (assumes normal operation and normal aging) |
|
|
|
|
|
NIST Traceable Calibration Certificates
To assist our customers in satisfying ISO-9001:2000, section 8.2, certified monitor and measurement calibration requirements, ATEQUIP.com can supply for all of the Vitrek products, certified NIST traceable calibration certificates from an ANSI/NCSL Z540-1-1994 compliant-accredited/ ISO 17025 accredited calibration laboratory. Please contact us directly for information on your specific test equipment interest. |
|
Please-mail ATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.
[Back to Top]
|
|
|
Prices listed in the table below are in US$ and apply to North American destinations only.
|
Fluke Model |
Description |
Data Sheet |
|
| Fluke Ti 20 |
Thermal Imager |
|
$7166.00
|
|
| Fluke Ti 10 |
Thermal Imager |
|
$4495.00
|
|
| Fluke Ti R |
Thermal Imager |
|
$4495.00
|
|
| Fluke Ti R1 |
Thermal Imager |
|
$6995.00
|
|
Fluke Ti20 TFLUKE Ti20 Thermal Imagers | Ti20 Thermal Imaging Camera |
|
|
|
|