Built-in 8 Channel ScannerTests AC, DC Hipot, IR & Ground Bond to UL, CSA, IEC & TUV Specs
Up to 5KVAC 40mA
Up to 6KVDC 10mA
Multi-mode Insulation Resistance IR 50-1000V up to 10,000MΩ
-
Ground Bond continuity up to 42Amps
Leakage current resolution down to 10μA
|
|
|
|
The V5 Sets the Standard for Versatility and Value.
Only Vitrek, the technology leader in electrical safety test automation, could build a feature rich, full function 5-in-1 Hipot Electrical Safety Tester with such high performance this high and a price this low. The new Vitrek V5 combines AC Hipot to 5KV, DC Hipot to 6KV, Insulation Resistance to 10 gig-ohms and high current Ground Bond measurement up to 42 Amps and a built-in 8 channel HV Scanner. And all this comes in one systems ready, low profile, rugged, rack mount package – complete with rear terminal outputs. ...
QuickTest automation software is an easy to load graphical test sequence development and operating environment platform. It provides time/date, operator, test parameters, test results and readings for review, printout or export to database program.
...Product Labeling UL
If you need one of these labels on your product, insist that the Vitrek label is on your Electrical Safety Compliance Tester. That's because the Vitrek V60 Series has been engineered and manufactured to meet the most demanding electrical product safety test requirements. So, whether your job is on an automated production line or in a product safety engineering lab, the V60 Series packs the performance you need to get the job done right - at a value price that won't break your budget.
Demand that the Vitrek V5 label is on your Hipoot Tester-Dielectric Analyzer. Only Vitrek minimizes overall test time and maximizes system reliability by combining four dielectric test functions in one unit.
It would hardly seem possible that a slow dielectric tester could back-up an entire production line. Yet with today's imposing 100% dielectric inspection requirements, the antiquated manual hipot tester is often the manufacturing bottleneck. Imagine the consequences of the tester breaking down or worse yet passing a defective product.
Just a few good reasons why each Vitrek V5 Multi-function Dielectric Analyzer is equipped with two high performance microprocessors - to speed testing throughput and to execute exhaustive onboard diagnostics. Simply put, the Vitrek V5 provides the fastest, most accurate and reliable test results available. And it does it for a surprisingly modest price.
QuickTest™ Software (Option QT-V5)
QuickTest automation software is an easy to load graphical test sequence development and operating environment platform. It provides time/date, operator, test parameters, test results and readings for review, printout or export to database program.
|
NIST Traceable Calibration Certificates Available |
To assist our customers in satisfying ISO-9001:2000, section 8.2,certified monitor and measurement calibration requirements, ATEQUIP.com can supply for all of the GW INSTEK products, certified NIST traceable calibration certificates from an ANSI/NCSL Z540-1-1994 compliant -accredited ISO 17025 accredited calibration laboratory. Please contact us directly for information on your specific test equipment interest. |
Vitrek V5 Programmable AC & DC Hipot~ Insulation Resistance~ Ground Bond~Ground Contunity Specifications |
AC Hipot |
Voltage Range: |
100 to 5000 VAC RMS |
Voltage Setting Resolution: |
5V/step |
Voltage Regulation: |
1% of reading + 5V |
Voltage Accuracy: |
1% of reading + 10V |
Voltage Monitoring: |
At Output Terminals |
Output Current: |
30mA to 40mA 180S max, 0 to 30mA continuous. Below 500V 10mA max |
Min/Max Current Limits: |
0.1 to 40mA |
Current Accuracy: |
1% of reading + 50mA |
DC Hipot |
Voltage Range: |
100 to 6000 VDC |
Voltage Setting Resolution: |
Resolution: 5V/step |
Voltage Regulation: |
1% of reading + 5V |
Voltage Accuracy: |
1% of reading + 10V |
Voltage Monitoring: |
At Output Terminals |
Output Current: |
10mA continuous, below 500VDC 2mA continuous |
Min/Max Current Limits: |
0.01 to 10mA |
Current Accuracy: |
1% of reading + 50mA |
Insulation Resistance |
| DC Output Voltage: |
50, 100, 500 or 1000V |
|
Resistance Range: (Full Scale) |
50MW |
200MW |
9999MW |
Resistance Range: |
10KW |
100KW |
1MW |
50, 100 VDC |
1-50MW 5%
51-200MW 10%
201-1999MW 20% |
500, 1000 VDC |
1-500MW 5%
501-2000MW 10%
2001-9999MW 20% |
| Multi-Mode IR™: |
Select 1 of 3 modes - test passes on good reading, test fails on bad reading, pass/fail determined at end of test time. |
Ground Bond and Ground Continunity |
Test Current: |
3A to 42 Amps RMS |
Terminal Configuration: |
4 wire Kelvin |
Resistance Range: |
0 to 600mW |
Resistance Resolution: |
100mW |
Resistance Accuracy: |
1% reading ± 3mW |
Compliance Voltage: |
8 volts at terminals |
Current Resolution: |
0.01A |
| Voltage Resolution: |
0.01V |
General Specifications |
Test Database: |
10 test sequences with up to 16 steps per test sequence |
Front Panel Lockout: |
Prevents database edit while in lockout mode |
Arc Detect: |
10 level trip select |
Remote Interfaces: |
RS232 - Fully interactive
PLC - Inputs; Start, Reset
Outputs: Testing, Pass, Fail
GPIB - Option GP-V5 |
Timer Accuracy: |
0.25% ± 50mS |
Power Source: |
AC100v, 120V, 220V, 230V (±10% 50/60Hz), 350W max |
Operating Environment: |
Indoor use, altitude up to 6500 ft (2000m). Installation Category II. Pollution Degree 2. |
Operating Temperature: |
0°C to 40°C, 80% RH |
Storage Temperature: |
-10°C to 70°C, 70% RH |
Dimension: |
17 W x 17 D x 5.25 H, (432mm x 432mm x 133mm) |
Weight: |
39lbs (18kg) net, 45 lbs (20kg) ship |
Accessories: |
TL-20-60 & K-2 Test Leads, Instruction Manual and Power Cord. |
| Compliance: |
CE Mark Certified to EN61010 and EMC Directives EN50081-1 & EN50082-2. |
Accuracy: |
Stated specifications apply for 1 year at 23°C ± 5°C. |
Warranty: |
* 3 Year Extended Warranty with registration and annual factory calibration, 1 year parts and labor standard. |
NIST Cal Cert.......Opt. NIST-V5 |
ANSI/NCSL Z540 Calibration Certification with data accuracy traceable to NIST |
QuickTest™ Software....... Option QT-V5: |
Bundled Test Automation Software and PC Serial Interface Cable. Easy to load graphical test sequence development and operating environment. Provides time/date, operator, test parameters, test results and readings. Results may be viewed, printed out or exported to a database program. |
|
ITEM |
Description |
Data Sheet |
Price |
Purchase |
V5 |
Hipot Electrical Safety Tester, Ground Bond Tester |
|
$4,990.00 |
Buy Now |
GP-V5 |
GPIB Interface Option |
|
495.00 |
Buy Now |
TL-115-5 |
Hipot/GB Outlet Test Adaptor |
|
195.00 |
Buy Now |
TL-10-60 |
High Voltage Probe Lead Set |
|
95.00 |
Buy Now |
TL-20-60 |
High Voltage Alligator Lead Set |
|
85.00 |
Buy Now |
TL-IEC5 |
IEC Socket Lead Set |
|
115.00 |
Buy Now |
K-2 |
High Current, 4-wire, 2 Clip Kelvin Lead Set |
|
185.00 |
Buy Now |
K-4 |
High Current, 4-wire, 4 Clip Kelvin Lead Set |
|
195.00 |
Buy Now |
SFI-2 |
Safety Fault Interrupt Option |
|
100.00 |
Buy Now |
MHL-4U |
Mating HV Lead 4 ft. unterminated |
|
45.00 |
Buy Now |
MHL-4A |
Mating HV Lead with Alligator Clip |
|
50.00 |
Buy Now |
| NIST-V5 |
Calibration Certification |
|
$125.00 |
Buy Now |
| QT-V5 |
QuickTest™ Software |
|
$295.00 |
Buy Now |
| |
|
|
|
|
|
|
|
|
|