NEWPORT's INFPT Series 6-DIGIT PROCESS TIMER / CONTROLLER / CLOCK
Multi-Function Configuration: Clock~Timer~Timer/Controller ~Stop Watch~ Built-in Date
The INFPT multifunctional panel meter is designed to be set up as a clock/timer controller or stopwatch. The unit contains eight different time bases and has a built-in date function. The meter employs five controller output modes, which enable the user to set up the unit to virtually any timer control application.
Life-Cycle Testing with RS232
The INFPT is perfectly suited for life cycle testing, turning four loads on and off based on timing cycle. The clock time base is derived from the 50 or 60 Hz power line and from the internal crystal oscillator. Front-panel pushbuttons provide a convenient means of configuration and access to the meter’s many features. These features can also be accessed through RS-232 or RS-485 serial communications. The front-panel displays values and messages with six, 14-segment LEDs.
INFP Panel Meter SPECIFICATIONS
Accuracy: max. error ±50 ppm over full temp range; Warmup to rated accuracy: 55 min
Display: 6-digit, 14 segment LED; 14.2 mm (0.56" H): 4 LED outputs to indicate ON or ACTIVE mode
Display Modes: 12-hour clock, 24-hour clock, 99-day, 99-hour, 99-minute, 999999-hour, 9999.99-hour, 9999.99-minute, 9999.99-sec
TTL Outputs: 4, standard; rated 150 mA at 1 V sink: 30 V open
Relay Outputs (optional): Dual relays, form C, 7A at 30 Vdc or 230 Vac
Four-Relay Board (optional): Dual 7 amp and Dual 1 amp form C relays
Power: 115 or 230 Vac ± 10%, 49-440 Hz (to 440 Hz with 110 or 220 V min)
Power Consumption: 3 to 10 Watts max.
GENERAL
Input Threshold: 1 V to 3.5 V
Protection Level: 24 Vdc
Connection: Two 3-Socket input plugs
Input Resistance: 30 kohm pull-up resistor to +5 V
Operating Ambient Range: 0 to 50°C (32 to 122°F)
Relative Humidity: 90% at 40°C (non-condensing)
Dimensions: 48 H x 96 W x 156 D mm (1.89" x 3.78" x 6.13")
Panel Cutout: 45 H x 96 W mm (1.772" x3.622"); 1/8 DIN
Weight: 574 g (1.27 lb)
Order Example Below Table: