BM25, BM400,
cart
atequip logo
Megger Motor Phase Rotation Testers 560060 560400 & Phase Sequence Testers 830220-1 PSI-700

Main Menu
 
New Product
Products
Megger Motor Phase Rotation Testers 560060 560400 & Phase sequence testers 830220-1 PSI-700

Biddle Megger 560060 & 560400 Motor Phase Rotation Tester

 

 

Biddle Megger Motor Rotation Phase Testers Models 560060 &560400

 

The Motor and Phase Rotation Tester permits the electrical contractor or industrial maintenance electrician to permanently connect and tape the terminals of the motor being installed, without having to first energize the motor by a temporary hookup from a power source, if available, to determine motor rotation. Therefore, the test set eliminates the need for temporary connections that can be time consuming, costly and quite hazardous, particularly where many large, high-voltage motors are involved.

Also, certain types of drives should never be rotated in the wrong direction. In such cases, the temporary hookup or trial method, having a fifty-fifty chance of being wrong, can do serious harm.

The three motor leads on the left side of the test set are for attachment to the terminals of the motor being tested for rotation determination.

Fuses are inserted in the motor A and C test leads as protection in the event the user accidentally touches these leads to an energized circuit. These standard fuses are easily removed and replaced from their panel-mounted holders.

The three lines leading to the right of the test set are for direct attachment to energized ac power systems up to 600 volts to determine the system phase sequence. A four-position switch selects the test to be made - system phase sequence, motor rotation and transformer polarity. The selector switch connects a D-size dry cell into the circuit when the rotation of a motor or the polarity of a transformer is being checked. In the OFF position, both the meter and the battery are disconnected from all circuits. A push switch is connected in series with the battery and opens the circuit during transformer polarity testing.

The dry cell is easily removed and replaced from its panel-mounted holder by a coin-slot access cap. The dc zero-center ammeter indicates correct or incorrect rotation or polarity by deflecting its pointer to the right or left. A zero or null adjuster is provided for the ammeter.

Features:

Complete phase-sequence and motor-rotation testing in one instrument

Ensures correct phase hookup in one easy

Rugged and portable

Performs additional polarity and continuity checks

ORDERING INFORMATION AT BOTTOM OF PAGE

 

Biddle Megger PSI-700 Phase Sequence Indicator

 

 

Megger’s PSI-700 Phase(Ǿ) Sequence Indicator

 

Megger’s Multi-Volt PSI-700 is a rugged, lightweight instrument used to determine the phase sequence or phase rotation of a three-phase system that also detects and identifies an open phase.

The Model PSI-700 Phase Sequencer is simple to use. Simply connect the provided Color-Coded Clip Leads to the system and a lamp will instantly indicate either ABC clockwise rotation or CBA counter-clockwise rotation. Three lamps will illuminate to indicate that all phase voltages are present. When a phase is open, only one lamp will illuminate and identify the open phase. No additional external power is required for the PSI-700 Phase Sequence Indicator.

 

Megger PSI-700 Phase Sequence Indicator Features

Voltage: For Use on 90 to 700 Volts, 3Ǿ, 50/60 Hz

Indicating Lamps: Five Lamps are Provided and Identified as to Function.

One Indicates ABC Clockwise Rotation

One Indicates CBA Counter-Clockwise Rotation

Three Lamps Are Identified As AǾ , BǾ And CǾ .

Leads: Color-Coded 40-Inch Leads With Insulated Clips Are Permanently Attached To The Instrument.

Does Not Require A Power Source

 

 

ORDERING INFORMATION LISTED BELOW

Megger 830220-1Power Cable Phase Sequence Meter

Megger’s 830220-1 Power Cable Phase(Ǿ) Sequence Meter

Megger's 830220-1 Phase Sequence Meter
Megger's Model 830220-1 Cable Phasing Meter offers a safe and quick method of measuring voltage and determining phase rotation of underground distribution systems using the capacitance test point of elbow connectors. Most manufacturers of high-voltage cable terminators incorporate capacitance test points into their elbow connectors. These test points are designed for measuring purposes.
Measures Voltage and Determines Phase Rotation
The Cable Phasing Meter is an instrument designed to measure voltage, determine phase rotation and phase out cables when connected to the capacitive test points. This instrument is battery operated and is supplied with a ground and two measuring leads.


MEGGER 830220-1 FEATURES AND BENEFITS
Safe - operates at low voltage
Measures system voltage
Measures capacitance of test point if system voltage is known
Checks phase rotation of cables
Phases out cables
Rugged; comes with portable case
Battery operated
Operates from potential test point of elbow connectors

ORDERING INFORMATION LISTED BELOW

Please e-mail ATEquip.com for Product Availabililty or a Price and Delivery Quotation. Thank you.

 
MEGGER 560060 ~ 560400 ~PSI-700 ~ 830220-1 ORDERING INFORMATION
    • BIDDLE Model
      Description
      Data
      MSRP
      Our Price
      Buy

      560060

      Megger® 560060 Motor and Phase Rotation Tester for 50/60 Hz

      $925.00
      $899.00
      560400

      Megger® 560400 Motor and Phase Rotation Tester for 25/50/60/400 Hz

      $1020.00
      $999.00
      PSI-700 Megger® PSI-700 Phase Sequence Indicator
      $485.00
      $475.00
      830220-1

      Megger® 830220-1 Power Cable Phase(Ǿ) Sequence Meter

      $2225.00
      $2199.00
    • Please e-mail ATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.

Megger Motor Phase Rotation Testers 560060 560400 & Phase sequence testers 830220-1 PSI-700 Motor Phase Rotation Testers 560060 560400

 
 


 