INSTEK Programmable glc-9000 mEDICAL eLECTRICAL sAFETY lEAKAGE cURRENT tESTER |
|
Instek ProgrammableGLC-9000 RS232~GPIB~USB Standard |
Instek GLC-9000 RS232 & GPIB Programmable Medical Electrical Safety Compliance Leakage Current Tester |
|
Instek GPC-9000 Tests Medical Device Leakage Currrents in Accordance with IEC 60601-1
Instek's GLC-9000, leakage current tester, is used to perform leakage current (or called touch current) tests on medical electrical (IEC 60601-1) and general purpose electric & electronic (IEC 60990) equipment. This tester engages with nine measurement networks (or called Measuring Device) to provide the simulation of human body while the EUT (equipment under test) is taking a leakage current testing in compliance with the specific standards or regulations such as IEC, UL, JIS...etc..
To provide a simple operation environment, the GLC-9000 equips with the large TFT LCD touch panel to configure systems as well as to present the measurement settings information and result simultaneously. There are 50 preset testing conditions, which conform to IEC60990 and other standards, for general electric equipment can be recalled to reduce the setting time. In addition, 30 sets empty memory are available for user defined setting.
A Meter mode is also available for the GLC-9000. It uses the measurement terminal (T1/T2) to measure voltage as the same way as that of an ordinary voltmeter. During the voltage measurement, the SELV function (safety extra low voltage) is applicable to detect whether the voltage value between measuring points exceed the SELV setting. |
Preset Test Conditions Designed into the Instek GLC-9000 Safety Tester
STANDARD |
APPLICABLE EQUIPMENT |
STANDARD |
APPLICABLE EQUIPMENT |
| IEC60950 |
Information Technology Equip. |
IEC60745 |
Handheld Electrical Motor Operated Tools |
| IEC60335 |
Household Electrical Appliances |
IEC60598 |
Lighting Producs and Luminaries |
| IEC60065 |
Audio-Video Electrical Products |
IEC61010 |
Elect. Measurement, Control, Lab Equip. |
|
Instek GLC-9000 Electrical Safety Tester Specifications |
| INPUT IMPEDANCE: 100Ω |
BASIC ACCURACY (*):±0.1% (R, Z, X, G, Y, B, L, C) |
TEST SPEED AC (> 2kHz) |
TEST SPEED DC |
MAX: 75mS |
MAX: 60mS |
FAST: 150mS |
FAST: 60mS |
MEDIUM: 450mS |
MEDIUM: 120mS |
SLOW: 600mS |
SLOW: 900mS |
TEST SIGNAL LEVELS:
≦3MHz:10mV~2Vrms, 1mV/Step or 10mV/Step, 2%±5mV
>3MHz:10mV~1Vrms, 1mV/Step or 10mV/Step, 2%±5mV |
| SHORT CIRCUIT CURRENT: Max. 20mA |
| MEASUREMENT RANGES |
| R~Z~X |
0.1mΩ ~ 100MΩ |
| G~Y~B |
10nS ~ 1000S |
| L |
0.1nH ~ 100kH |
| C |
0.01pF ~ 1F |
| D |
0.00001 ~ 9.9999 |
| Q |
0.1 ~ 9999.9 |
| θ |
-180° ~ +180° |
| Rdc |
0.1mΩ ~ 100MΩ |
| MEASUREMENT PARAMETERS: Impedance (Z), Phase Angle (θ), Inductance (L), Capacitance (C), AC Resistance (Rac), Quality Factor (Q), Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Susceptance (B), DC Resistance (Rdc) |
| SERIES OR PARALLEL EQUIVALENT CIRCUIT: C + R, C + D, C + Q, L + R, L + Q, L + D |
| SERIES EQUIVALENT CIRCUIT ONLY: X + R, X + D, X + Q |
| PARALLEL EQUIVALENT CIRCUIT ONLY: C + G, B + G, B + D, B + Q, B + R, L + G |
| POLAR FORM: Z + Phase Angle, Y + Phase Angle |
| AVERAGE: 1 ~ 256 TIMES |
| LCD DISPLAY: 320 x 240 DOT-MATRIX |
| INTERFACE: RS-232, GPIB Standard |
| POWER SOURCE: AC 115V(+10% / -25%), 230V(+15% / -14%) (Selectable), 50/60Hz |
| DIMENSIONS & WEIGHT: 330(W) x 170(H) x 340(D)mm, Approx. 5kg |
(*):Basic accuracy varies with the speed, frequency, AC signal level and impedance of the device under test. |
|
Instek GLC-9000 MedicAl Safety Compliance Leakage Current Tester Ordering Information |
| Instek P/N |
|
Data sheet
|
Instek MSRP |
Sale Price |
Purchase Now |
| GLC-9000 |
InstekGLC-9000 Compliance Tester +RS232+GPIB+USB |
2.6MB |
$2995.00
|
|
| Order Includes:
User manual x1, Power cord x2, Test lead (GTL-117) x2, Alligator clips x4(Red x2 / black x2), Foil probe x1
|
|
Please-mail ATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.

|
InstINSTEK Programmable glc-9000 mEDICAL eLECTRICAL sAFETY lEAKAGE cURRENT tESTER GLC-9000
|
|
 |