Fluke Precision AC Power Analyzers 4000 & 5000 | Fluke-N4K 1PP42 | Fluke-N4K 3PP42 | Fluke-N4K 3PP42I | Fluke-N4K 3PP42IP | Fluke-N4K 3PP42B | Fluke-N4K 3PP42IB | Fluke-N4K 3PP42IPB | Fluke-N4K 3PP50 | Fluke-N4K 3PP50I | Fluke-N4K 3PP50IP | Fluke-N4K 3PP50IP Fluke-N4K 3PP54I | Fluke-N4K 3PP54IP | Fluke-N5K 3PP50 | Fluke-N5K 3PP50I | Fluke-N5K 3PP50IP | Fluke-N5K 3PP54 | Fluke-N5K 3PP54I | Fluke-N5K 3PP54IP | Fluke-N5K 3PP64 | Fluke-N5K 3PP64I | Fluke-N5K 3PP64IP | Fluke-N5K 4PP54 | Fluke-N5K 4PP54IP | Fluke-N5K 6PP54I | Fluke-N5K 6PP54IP | Fluke-N5K 6PP64I | Fluke-N5K 6PP64IP | FLUKE-N5K 6PP64IPR | FLUKE-N5K 6PP64IR |
|
|
Fluke Norma Precision AC Power Analyzers Models 4000 & 5000 |
Fluke Norma High Precision Power Analyzers Digital Wattmeters |
|
Fluke's Norma 4000 & 5000 Series AC Power Analyzers ~ AC Wattmeters features 10MHz Bandwidth
Compact Fluke Norma 4000 & 5000 Series AC Power Analyzers/ AC Wattmeters include the latest AC Power measurement technology to assist engineers working with motors, inverters, lighting, power supplies in improving their product's efficiency. Based on patented high-bandwidth architecture, Fluke Norma 4000 & 5000 Series AC Power Analyzers deliver precise measurements of single or three-phase current and voltage, Harmonic Analysis, Fast Fourier Transformation (FFT) analysis, as well as calculations of power and other derived AC power related parameters. The Fluke 4000 & 5000 provide class-leading accuracy and common mode rejection (CMR) for any waveform, frequency or phase shift.
The Fluke 4000 and 5000 Precision AC Power Analyzers offer easy and straight-forward operation with unmatched price performance. Features include: 1 to 3 power phases, 5.7” / 144 mm color display, harmonic analysis, scope mode, vector diagram display, recorder function, Fluke NormaView PC software and expandable 4 MB RAM data memory.
Fluke Norma 4000: Ideal for field testing, the Fluke Norma 4000 power analyzer offers easy and straight-forward operation. Features include: 1 to 3 power phases, 5.7” / 144 mm color display, harmonic analysis, FFT analysis, scope mode, vector diagram display, recorder function, Fluke NormaView PC software, and 4 MB RAM data memory.
Fluke Norma 5000: Providing the highest bandwidth on the market, the Fluke Norma 5000 Six-Phase Power Analyzer is the ideal test and analysis tool for the development of frequency converters and lighting equipment. Features include: 3 to 6 power phases, optional internal printer, and all of the Fluke Norma 4000 features and functionality described above.
Measure Test & Analyze AC Power Applications with High Precision and Ease
Fluke Norma 4000 and Fluke Norma 5000 power analyzers accurately measure current and voltage and calculate active, reactive and apparent power and calculate other derived values from these high-precision measurements. Accuracy is not affected by either the waveform shape or frequency over a wide range. Phase shift accuracy is maintained due to the input channel design. Harmonics are calculated up to half of the sampling rate. The DSO function represents measured input parameters as waveforms. Voltage and current can be measured directly via the instrument’s integrated voltage dividers and shunts. It is also possible to connect external voltage dividers as well as shunts or current probes for specific applications. Options such as additional interfaces, analogue inputs and outputs are also available. The analyzer firmware can be updated via the standard RS232 interface.
High Precision AC Power Analysis Measurements
Fluke Norma Series power analyzers are designed to measure signals in a wide frequency range from dc to MHz. The input stages are dc coupled and designed to handle high rise time signals. A zero and offset calibration against a stable voltage reference runs automatically over short time periods to stabilize the accuracy. technology of barriers for high channel isolation and common mode rejection. This makes Fluke Norma Series power analyzers suitable for special applications, such as the switching waveforms present on variable frequency drives or high efficiency lighting loads.
Long Time Long Term 2-Year AC Power Analyzer Accuracy
Fluke Norma Series power analyzers maintain high performance and reliable accuracy within the industry’s longest recommended recalibration interval of two years. This long interval reduces downtime and saves service costs
Measures Up to 1500Amps Direct
The input modules can handle up to 10 A or 20 A directly or measure current via wideband precision shunts. The available range of shunts enables measurements up to 1500 A and can be used in conjunction with all of the available input modules.
Optional Process Interface for Motor Power Measurements
The optional process interface can be used with both Fluke Norma 4000 and Fluke Norma 5000 power analyzers. It provides the simultaneous recording of torque (M), speed (N) and mechanical power (Pm) of up to four motors. Each of the eight inputs is switchable between analog (voltage) or digital (frequency) input. This interface provides synchronous capture at a sample rate of 34 kHz. The interface also provides four analog outputs, which are updated after every average interval. By inputting the additional analog and digital values it is possible to fully evaluate electrical and mechanical efficiency in real time.
Powerful Norma PC Software for AC Power Analyzer Applications
The Fluke NormaView software improves operation efficiency of the analyzers by enabling instrument setup settings to be saved and stored along with the measurement data. Instrument setups can be used for particular measurement tasks. Settings can be easily uploaded to the instrument with just a few mouse clicks. The software also enables quick and easy data download, analysis and report writing.
Fluke 4000 AC Power Analyzer Modular Power Phases
The Fluke Norma 4000 power analyzer can be equipped with up to three power phases, and the Fluke Norma 5000 power analyzer can be equipped with up to six power phases. Users can select the type of power phase best suited for their application from a variety of optional power phases. Specifications vary depending on the model of the power phase.
Each modular plug-in power phase consists of a voltage and a current measurement channel. Each measuring channel is available for each basic unit. However, only one kind of channel can be used per unit (see standard configurations).
Applications
Electric motors – Complete measurements of both electrical and mechanical power values with an uncertainty of only 0.1%. Through detailed spectrum analysis and dynamic torque calculation capabilities, switching losses caused by the inverter are accurately measured, and a thorough evaluation is made of torque transients and harmonics at higher frequencies
Inverter Drive Systems – Simultaneous measurement of all electrical and mechanical power parameters in the same time window enables users to observe the influence one component has on another, or on the whole system.
Lighting Systems – Unique bandwidth of up to 10 MHz and a high sampling rate up to 1 MHz provide detailed signal analysis at ballast outputs. A unique shunt technology enables power measurements at very high frequencies. Simultaneous measurement of input and output power provides instant calculation of ballast losses
Transformers – Synchronous six-phase power measurements enable highly accurate efficiency and loss calculations of large power transformers even at very low power factors. Synchronous multiphase resistance measurements are also possible of transformer coils. The internal formula editor enables voltage ratio calculations, and the combination of high-precision fundamental values and wide bandwidth provides detailed harmonics analysis.
Automotive – Detailed analysis of all electrical and mechanical components installed in modern cars for developing strategies that help reduce fuel consumption or the increase the range of electric vehicles. Synchronous electrical input and mechanical output measurements provide complete data on the efficiency and losses of individual components as well as the whole drive system.
The Fluke NormaView software improves operation efficiency of the analyzers by enabling instrument setup settings to be saved and stored along with the measurement data. Instrument setups can be used for particular measurement tasks. Settings can be easily uploaded to the instrument with just a few mouse clicks. The software also enables quick and easy data download, analysis and report writing.
Recommended Accessory Current Shunts for the 4000 and 5000 AC Power Analyzers
The input modules can take up to 10 A or 20 A directly or measure current via wideband precision shunts. The available range of shunts enable measurements up to 1500 A and can be used in conjunction with all of the available input modules. For available current shunt ranges, please see values and models listed below in the ordering information secation.
Fluke's Wide band High Amperage Current Shunts |
-
Fluke
High Current Wide band Current Shunts
 Fluke 32A Planar Shunt
|
| Fluke 4000 & 5000 AC Power Analyzer Standard Configurations |
Fluke 4000 & 5000 AC Power Analyzer Standard Configurations |
Power ø Type |
|
Order Number |
Description |
PP42 |
PP50 |
PP54 |
PP64 |
# ø |
GPIB /Lan |
Inter- face |
Fluke-N4K 1PP42 |
AC Power Analyzer 4000, single phase with PP42 power phase input module |
● |
|
|
|
1 |
|
|
Fluke-N4K 3PP42 |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules |
● |
|
|
|
3 |
|
|
Fluke-N4K 3PP42I |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
● |
|
|
|
3 |
● |
|
Fluke-N4K 3PP42IP |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
● |
|
|
|
3 |
● |
● |
Fluke-N4K 3PP42B |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with current binding post |
● |
|
|
|
3 |
|
|
Fluke-N4K 3PP42IB |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with current binding post with IEEE488/ Ethernet (IFC1) interface |
● |
|
|
|
3 |
● |
|
Fluke-N4K 3PP42IPB |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with current binding post with IEEE488/ Ethernet interface and analog / digital input output channels (PI1) |
● |
|
|
|
3 |
● |
● |
Fluke-N4K 3PP50 |
AC Power Analyzer 4000, three phase with 3 x PP50 power phase input modules |
|
● |
|
|
3 |
|
|
Fluke-N4K 3PP50I |
AC Power Analyzer 4000, three phase with 3 x PP50 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
|
● |
|
|
3 |
● |
|
Fluke-N4K 3PP50IP |
AC Power Analyzer 4000, three phase with 3 x PP50 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
● |
|
|
3 |
● |
● |
Fluke-N4K 3PP50IP |
AC Power Analyzer 4000, three phase with 3 x PP50 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
● |
|
|
3 |
● |
● |
Fluke-N4K 3PP54I |
AC Power Analyzer 4000, three phase with 3 x PP54 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
|
|
● |
|
3 |
● |
|
Fluke-N4K 3PP54IP |
AC Power Analyzer 4000, three phase with 3 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
|
● |
|
3 |
● |
● |
Fluke-N5K 3PP50 |
AC Power Analyzer 5000, three phase with 3 x PP50 power phase input modules |
|
● |
|
|
3 |
|
|
Fluke-N5K 3PP50I |
AC Power Analyzer 5000, three phase with 3 x PP50 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
|
● |
|
|
3 |
● |
|
Fluke-N5K 3PP50IP |
AC Power Analyzer 5000, three phase with 3 x PP50 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
● |
|
|
3 |
● |
● |
Fluke-N5K 3PP54 |
AC Power Analyzer 5000, three phase with 3 x PP54 power phase input modules |
|
|
● |
|
3 |
|
|
Fluke-N5K 3PP54I |
AC Power Analyzer 5000, three phase with 3 x PP54 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
|
|
● |
|
3 |
● |
|
Fluke-N5K 3PP54IP |
AC Power Analyzer 5000, three phase with 3 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
|
● |
|
3 |
● |
● |
Fluke-N5K 3PP64 |
AC Power Analyzer 5000, three phase with 3 x PP64 power phase input modules |
|
|
|
● |
3 |
|
|
Fluke-N5K 3PP64I |
AC Power Analyzer 5000, three phase with 3 x PP64 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
|
|
|
● |
3 |
● |
|
Fluke-N5K 3PP64IP |
AC Power Analyzer 5000, three phase with 3 x PP64 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
|
|
● |
3 |
● |
● |
Fluke-N5K 4PP54 |
AC Power Analyzer 5000, four phase with 4 x PP54 power phase input modules |
|
|
● |
|
4 |
|
|
Fluke-N5K 4PP54IP |
AC Power Analyzer 5000, four phase with 4 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
|
● |
|
4 |
● |
● |
Fluke-N5K 6PP54I |
AC Power Analyzer 5000, six phase with 6 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface |
|
● |
|
|
6 |
● |
|
Fluke-N5K 6PP54IP |
AC Power Analyzer 5000, six phase with 6 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
● |
|
|
6 |
● |
● |
Fluke-N5K 6PP64I |
AC Power Analyzer 5000, six phase with 6 x PP64 power phase input modules with IEEE488 / Ethernet (IFC1) interface |
|
|
|
● |
6 |
● |
|
Fluke-N5K 6PP64IP |
AC Power Analyzer 5000, six phase with 6 x PP64 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
|
|
|
● |
6 |
● |
● |
|
Fluke Norma High Precision AC Power Analyzers |
|
Compact design makes it easy to carry and saves working space. |
|
Simple user interface ensures easy, intuitive operation |
|
variety of standard configurations allows users to choose the exact functionality required for their unique application. |
|
Simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events on all phases at exactly the same point in time. |
|
All inputs are galvanically isolated to avoid short circuits in all applications. |
|
Voltage, current and power harmonics measured up to the 40th harmonic for complete analysis. |
|
FFT analysis, vector diagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete analysis capability |
|
User-selectable average time – from 15ms up to 3600s – for dynamic measurements. |
|
4 MB on-board memory (expandable to 128 MB) for storage of measured values. |
|
Fast and easy connection to a PC – RS232 and USB included as standard; optional IEEE488, Ethernet, or USB2.0. |
|
PI1 process interface to measure torque and speed with external sensors, plus four analog outputs for easy use on motor and drive applications. |
|
341kHz or 1 MHz sample rates for detailed signal analysis |
|
Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision. |
|
Fluke NormaView PC software for data download, analysis & report writing. |
|
Fluke 10 A Triaxial Shunt with Cables (0.333 Ω, 0 to 0.5 MHz) |
|
Fluke 30 A Triaxial Shunt with Cables (0.010 Ω, 0 to 0.5 MHz) |
|
Fluke 100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz) |
|
Fluke 150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz) |
|
Fluke 300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz) |
|
Fluke 500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz) |
|
Fluke LG Shunt Cables for High Current Shunts |
NORMA VIEW 
Software |
NORMA VIEW Software
NORMA View is a Microsoft Windows®-based software package that provides an easy to-
use, intuitive graphical interface to the Fluke Norma 4000/5000 Power Analyzer.
NORMA View makes it easy to configure the power analyzer and recall data
measurements. It has a fully featured stand-alone user interface for implementing
functions as well as error checking and tracing. NORMA View has been developed using LabVIEW 7, a graphical development system by National Instruments Corporation.
Easy-to-use user color interface
• Modular application concept with dynamically loaded plug-ins
• Configuration storage to file in instrument memory
• Data measurement storage to disk in Excel-like format
• Multilanguage support
• Data measurement visible including the status of each measurement
• Based on LabVIEW lnopa01 instrument driver
• Error codes compatible with VISA standard
NORMA View is a Microsoft Windows®-based software package that provides an easy to-
use, intuitive graphical interface to the Fluke Norma 4000/5000 Power Analyzer.
NORMA View makes it easy to configure the power analyzer and recall data
measurements. It has a fully featured stand-alone user interface for implementing
functions as well as error checking and tracing. NORMA View has been developed using LabVIEW 7, a graphical development system by National Instruments Corporation.
Easy-to-use user color interface
• Modular application concept with dynamically loaded plug-ins
• Configuration storage to file in instrument memory
• Data measurement storage to disk in Excel-like format
• Multi language support
• Data measurement visible including the status of each measurement
• Based on LabVIEW lnopa01 instrument driver
• Error codes compatible with VISA standard
~NORMA 4000 & 5000 Software User's Guide
|
|
~DATA SHEET |
OPERATOR'S MANUAL~ |
Please e-mail ATEquip.com for Fluke 2801 & 2802 Availability or a Price and Delivery Quotation. Thank you.  |
|
| |
Fluke AC Power Analyzer 4000 & 5000 Ordering Information |
Model |
Description |
MSRP |
Price |
Buy Now |
Fluke-N4K-1PP42 |
AC Power Analyzer 4000, single phase with 1 x PP42 power phase input module
|
$7,196.00 |
$6,980.00 |
|
| FLUKE-N4K-2PP42I |
AC Power Analyzer 4000, Dual phase with 2 x PP42 power phase input modules |
$11,001.00 |
$10,670.00 |
|
| Fluke-N4K-3PP42 |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules |
$11,065.00 |
$10,733.00 |
|
| FLUKE-N4K-PP42B |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with current binding post |
$11,624.00 |
$11,275.00 |
|
Fluke-N4K-3PP42I |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
$15,780.00 |
$15,306.00 |
|
| FLUKE-N4K-3PP42IB |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with current binding post with IEEE488/ Ethernet (IFC1) interface |
$16,349.00 |
$15,858.00 |
|
Fluke-N4K-3PP42IP |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$18,035.00 |
$17,493.00 |
|
| FLUKE-N4K-3PP42IPB |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) w/current binding posts |
$18,604.00 |
$18,045.00 |
|
Fluke-N4K-3PP50 |
AC Power Analyzer 4000, three phase with 3 x PP42 power phase input modules with current binding post with IEEE488/ Ethernet interface and analog / digital input output channels (PI1) |
$12,172.00 |
$11,806.00 |
|
Fluke-N4K 3PP50I |
AC Power Analyzer 4000, three phase with 3 x PP50 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
$16,908.00 |
$16,400.00 |
|
Fluke-N4K-3PP50IP |
AC Power Analyzer 4000, three phase with 3 x PP50 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$19,163.00 |
$18,588.00 |
|
| Fluke-N4K-3PP52IB |
AC Power Analyzer 4000, three phase W/52BP/IFC2 |
$15,555.00 |
$15,088.00 |
|
| Fluke-N4K-3PP541 |
AC Power Analyzer 4000, three phase W/54/IFC1 |
$16,067.00 |
$15,584.00 |
|
| Fluke-N4K-3PP541P |
AC Power Analyzer 4000, three phase W/54/IFC1 & PI1 |
$18,322.00 |
$17,772.00 |
|
| Fluke-N4K-Rack-Kit |
AC Power Analyzer 4000 19 inch Rack Mount Kit W/Handles |
$218.00 |
$218.00 |
|
| Fluke-N5K-3PP50 |
AC Power Analyzer 5000, three phase W/50 |
$14,226.00 |
$13,799.00 |
|
| Fluke-N5K-3PP501 |
AC Power Analyzer 5000, three phase POWER ANALYZER W/50/IFC1 |
$16,744.00 |
$16,241.00 |
|
| Fluke-N5K-3PP501P |
AC Power Analyzer 5000, three phase W/50/IFC1 & PI1 |
$18,999.00 |
$18,429.00 |
|
| Fluke-N5K-3PP501R |
AC Power Analyzer 5000, three phase W/50/IFC2/PRNTR |
$17,870.00 |
$17,333.00 |
|
Fluke-N5K-3PP54 |
AC Power Analyzer 5000, three phase with 3 x PP54 power phase input modules |
$15,775.00 |
$15,301.00 |
|
Fluke-N5K-3PP54I |
AC Power Analyzer 5000, three phase with 3 x PP54 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
$18,322.00 |
$17,772.00 |
|
Fluke-N5K-3PP54IP |
AC Power Analyzer 5000, three phase with 3 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$20,577.00 |
$19,959.00 |
|
| Fluke-N5K-3PP54IR |
AC Power Analyzer 5000, three phase W/54/IFC2/PRNTR |
$19,219.00 |
$18,642.00 |
|
| Fluke-N5K-3PP54R |
AC Power Analyzer 5000, three phase W/54/PRNTR |
$14,550.00 |
$14,113.00 |
|
Fluke-N5K-3PP64 |
AC Power Analyzer 5000, three phase with 3 x PP64 power phase input modules |
$18,885.00 |
$18,318.00 |
|
Fluke-N5K-3PP64I |
AC Power Analyzer 5000, three phase with 3 x PP64 power phase input modules with IEEE488/ Ethernet (IFC1) interface |
$22,955.00 |
$22,266.00 |
|
Fluke-N5K-3PP64IP |
AC Power Analyzer 5000, three phase with 3 x PP64 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$25,251.00 |
$24,493.00 |
|
| Fluke-N5K-3PP64IPR |
AC Power Analyzer 5000, three phase W/64/IFC2 & PI1/PRNTR |
$26,379.00 |
$25,587.00 |
|
| Fluke-N5K-3PP64IR |
AC Power Analyzer 5000, three phase W/64/IFC2/PRNTR |
$24,037.00 |
$23,315.00 |
|
| Fluke-N5K-3PP641 |
AC Power Analyzer 5000, three phase W/64/IFC1 |
$32,088.00 |
$31,125.00 |
|
Fluke-N5K-4PP54 |
AC Power Analyzer 5000, four phase with 4 x PP54 power phase input modules |
$16,882.00 |
$16,375.00 |
|
Fluke-N5K-4PP54IP |
AC Power Analyzer 5000, four phase with 4 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$22,494.00 |
$21,819.00 |
|
| Fluke-N5K-PP421B |
AC Power Analyzer 5000,six phase W/42BP/IFC2 |
$21,520.00 |
$20,874.00 |
|
| Fluke-N5K-6PP421BR |
AC Power Analyzer 5000,six phase W/42BP/IFC2/PRNTR |
$24,800.00 |
$24,056.00 |
|
| Fluke-N5K-6PP501 |
AC Power Analyzer 5000,six phase W/50/IFC2 |
$22,704.00 |
$22,022.00 |
|
| Fluke-N5K-6PP501P |
AC Power Analyzer 5000,six phase W/50/IFC2 |
$25,062.00 |
$24,310.00 |
|
| Fluke-N5K-6PP501PR |
AC Power Analyzer 5000,six phase W/50/IFC2 & PI1/PRNTR |
$28,342.00 |
$27,491.00 |
|
| Fluke-N5K-6PP501R |
AC Power Analyzer 5000,six phase W/50/IFC2/PRNTR |
$26,000.00 |
$25,220.00 |
|
Fluke-N5K-6PP54I |
AC Power Analyzer 5000, four phase with 4 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$25,877.00 |
$25,100.00 |
|
Fluke-N5K-6PP54IP |
AC Power Analyzer 5000, six phase with 6 x PP54 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$28,132.00 |
$27,288.00 |
|
| Fluke-N5K-6PP54IPR |
AC Power Analyzer 5000,six phase W/54/IFC2 & PI1/PRNTR |
$26,676.00 |
$25,875.00 |
|
| Fluke-N5K-6PP54IR |
AC Power Analyzer 5000,six phase W/54/IFC2/PRNTR |
$24,333.00 |
$23,603.`00 |
|
Fluke-N5K-6PP64I |
AC Power Analyzer 5000, six phase with 6 x PP64 power phase input modules with IEEE488 / Ethernet (IFC1) interface |
$32,088.00 |
$31,125.00 |
|
Fluke-N5K-6PP64IP |
AC Power Analyzer 5000, six phase with 6 x PP64 power phase input modules with IEEE488 / Ethernet (IFC1) interface and analog / digital input output channels (PI1) |
$34,384.00 |
$33,352.00 |
|
| Fluke-N5K-6PP64IPR |
AC Power Analyzer 5000,six phase W/64/IFC2 & PI1/PRNTR |
$36,373.00 |
$35,281.00 |
|
| Fluke-N5K-6PP64IR |
AC Power Analyzer 5000,six phase W/64/IFC2/PRNTR |
$33,979.00 |
$32,959.00 |
|
| Fluke-N5K-Rack-Kit |
AC Power Analyzer 5000 19 inch Rack Mount Kit W/Handles |
$216.00 |
$216.00 |
|
Fluke-3024677 |
Fluke 32 A Planar Shunt |
$805.00 |
$780.00 |
|
Fluke-3024689 |
Fluke Cables for 32 A Planar Shunt |
$154.00 |
$154.00 |
|
Fluke-3024886 |
Fluke 10 A Triaxial Shunt with Cables (0.333 Ω, 0 to 0.5 MHz) |
$1,179.00 |
$1,143.00 |
|
Fluke-3024899 |
Fluke 30 A Triaxial Shunt with Cables (0.010 Ω, 0 to 0.5 MHz) |
$1,302.00 |
$1,262.00 |
|
Fluke-3024847 |
Fluke 100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz) |
$1,979.00 |
$1,919.00 |
|
Fluke-3024858 |
Fluke 150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz) |
$4,095.00 |
$3,972.00 |
|
Fluke-3024864 |
Fluke 300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz) |
$3,603.00 |
$3,494.00 |
|
Fluke-3024873 |
Fluke 500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz) |
$4,054.00 |
$3,932.00 |
|
Fluke-3024692 |
Fluke LG Shunt Cables for High Current Shunts |
$242.00 |
$242.00 |
|
|
|
|
|
Please e-mail ATEquip.com for Xitron 2801 &2802 Availability or a Price and Delivery Quotation. Thank you. |
|
Fluke Precision AC Power Analyzers 4000 & 5000 | Fluke-N4K 1PP42 | Fluke-N4K 3PP42 | Fluke-N4K 3PP42I | Fluke-N4K 3PP42IP | Fluke-N4K 3PP42B | Fluke-N4K 3PP42IB | Fluke-N4K 3PP42IPB | Fluke-N4K 3PP50 | Fluke-N4K 3PP50I | Fluke-N4K 3PP50IP | Fluke-N4K 3PP50IP Fluke-N4K 3PP54I | Fluke-N4K 3PP54IP | Fluke-N5K 3PP50 | Fluke-N5K 3PP50I | Fluke-N5K 3PP50IP | Fluke-N5K 3PP54 | Fluke-N5K 3PP54I | Fluke-N5K 3PP54IP | Fluke-N5K 3PP64 | Fluke-N5K 3PP64I | Fluke-N5K 3PP64IP | Fluke-N5K 4PP54 | Fluke-N5K 4PP54IP | Fluke-N5K 6PP54I | Fluke-N5K 6PP54IP | Fluke-N5K 6PP64I | Fluke-N5K 6PP64IP | FLUKE-N5K 6PP64IPR | FLUKE-N5K 6PP64IR
|
|
|