cart
atequip logo
Fluke Hart Scientific 5640 5641 5642 5643 5644 Thermistor Standards RTD Temperature Detector Probes

Main Menu
 
New Product
Products
70KV High Voltage Meter
Fluke Hart Scientific 5640 5641 5642 5643 5644 RTD Temperature ProbeDetectors
Fluke Hart Scientific 5640 5641 5642 5643 5644 Highly Accurate Thermistor RTD Standards Resistance Temperature Detectors-Sensors-Probes
FLUKE
Fluke Hart Scientific 5640 5641 5642 5643 & 5644 Thermistor Probes Highly Accurate yet Economical

Fluke Hart Scientific 5640 5641 5642 5643 & 5644 Thermistor Resistance RTD Temperature Standards Detector/Sensors

Thermistor Standards Probes are rugged, precision temperature sensors suitable for use as secondary or working temperature standards for laboratory metrology applications. Because Thermistor Probes generally are not affected by shock and vibration, you can use them in the most difficult field environments without worrying about calibration integrity.  Hart's 5640 5641 5642 5643 & 5644 Thermistor Temperature probe design uses an ultra-stable glass thermistor enclosed in a thin-wall stainless steel tube. The basic semiconductor element is a bead of manganese, nickel, and cobalt oxides mounted on 0.1 mm platinum wires. For long-term stability, the thermistor is aged at various temperatures for 16 weeks. During the aging process, verification of the probe’s stability is done to ensure performance to published specs.

Fluke Hart Scientific 5640 5641 5642 5643 & 5644 RTD Thermistor Temperature Probe/Detectors Datasheet

Fluke Hart Scientific 5640 5641 5642 5643 & 5644 Thermistor Standards RTD Reference Detector-Thermometers

Highly Accurate Excellent Stability Thermistor Temperature RTD Probes ~ Great Prices!

If you want a high-accuracy probe with excellent stability at a great price, the Model 5640-series Thermistor Standards Probes give you all three in a great package. Why pay for an SPRT when you can get ±0.001 °C accuracy from 0 °C to 60 °C in a calibrated thermistor probe for about one-third the cost of an uncalibrated SPRT alone? 

Hart's 5640 Series Thermistor Probes offer ±0.002 °C or ±0.005 °C Stability for One Full Year

Hart's 5640, 5641, and 5642 Thermistor Probes are designed for the temperature range of 0 °C to 60 °C. Hart's 5643 and 5644 Thermistor Probes span the 0 °C to 100 °C temperature range. Hart's 5640 Series offer stability of either ±0.002 °C or ±0.005 °C. These stability levels are guaranteed for one full year. 

NIST Traceable Calibration Provided with each HART 5640 5641 5642 5643 & 5644 Thermistor Probe

Precision calibration, traceable to NIST, is provided with each probe. A computer-generated table in increments of 0.01 °C is furnished with each calibration based on the formula: 

R=exp(A + B/T + C/T2 + D/T3)

The constants for the formula are obtained from a polynomial regression performed on the calibration data obtained. Over the range of 0 °C to 60 °C, calibration is performed at the triple point of water (0.01 °C) and 15 °C, 25 °C, 30 °C, 37 °C, 50 °C and 60 °C. For the 0 °C to 100 °C temperature range, the additional calibration points of 80 °C and 100 °C are used.  Each probe is individually calibrated and includes a report of calibration from the manufacturer. Contact Hart for calibration in Hart’s NVLAP accredited lab. 

Use 5640 5641 5642 5643 & 5644 Thermistor Probes with Hart Scientific Temperature Readouts

Combine these probes with Hart’s 1560 Black Stack thermometer to read directly in  °C,  °F, or K. This combination gives you resolution of 0.0001°C and total system accuracy is better than ±0.004 °C.  Compare the cost of a 5640 calibrated probe and a Hart 1560 Black Stack Thermometer Readout to the cost .

Hart 5640 ~ 5641 ~ 5642 ~ 5643 ~ 5644 ~ Thermistor RTD Temperature Probe Specifications

Temperature range 

(Nominal Resistance at 25 °C)

Range
Nominal Resistance@ 25°C
5640: 0 °C to 60 °C  
4.4KΩ
5641: 0 °C to 60 °C
5 K Ω
5642: 0 °C to 60 °C
4 K Ω
5643: 0 °C to 100 °C
10KΩ 
5644: 0 °C to 100 °C 
10KΩ 
Accuracy ( 0 °C to 60 °C)/Drift °C/Year
Accuracy
Drift
5640: ± 0.0015 °C
± 0.005 °C/Year
5641: ± 0.001 °C 
± 0.002 °C/Year
5642: ± ± 0.001 °C 
± 0.002 °C/Year
5643: ± 0.0015 °C
± 0.005 °C/Year
5644: ± 0.0015 °C
± 0.005 °C/Year
Accuracy ( 0 °C to 100 °C)/Drift °C/Year
5643: ± 0.0025 °C
± 0.005 °C/Year
5644: ± 0.0025 °C
± 0.005 °C/Year
Calibratiion Not included, long-term drift resistance traceability adds additional ± 0.0025 %. 
Lead Termination 4-Wire Kelvin
Size and Termination See below Ordering Information
Please e-mail
ATEquip.com for Product Availability or a Price and Delivery Quotation. 858-756-8742
Fluke Hart 5640 5641 5642 5643 5644 ORDERING INFORMATION Data sheet
Model
Description
Featured Price
 
Email ATEquip for Price and Delivery Quotation Email
     

Fluke Hart 5640-B

6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD, terminated in bare wire   Buy Now
Fluke Hart 5640-D 6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD, terminated in 5-pin DIN for Tweener Thermometers   Buy Now
Fluke Hart 5640-G 6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in gold pins   Buy Now

Fluke Hart 5640-I

6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in INFO-CON for 1521 or 1522   Buy Now
Fluke Hart 5640-J 6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in banana plugs   Buy Now
Fluke Hart 5640-L 6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in mini spade lugs   Buy Now

Fluke Hart 5640-M

6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in mini banana plugs   Buy Now
Fluke Hart 5640-P 6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in INFO-CON for 1523 or 1524   Buy Now
Fluke Hart 5640-S 6.35 x 229 mm (0.25 x 9 in) Thermistor Probe RTD terminated in Spade Lugs   Buy Now

Fluke Hart 5641-B

3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in bare wire   Buy Now
Fluke Hart 5641-D 3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in 5-pin DIN for Tweener Thermometers   Buy Now
Fluke Hart 5641-G 3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in gold pins   Buy Now

Fluke Hart 5641-I

3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in INFO-CON for 1521 or 1522   Buy Now
Fluke Hart 5641-J 3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in banana plugs   Buy Now
Fluke Hart 5641-L 3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in mini spade lugs   Buy Now

Fluke Hart 5641-M

3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in mini banana plugs   Buy Now
Fluke Hart 5641-P 3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in INFO-CON for 1523 or 1524   Buy Now
Fluke Hart 5641-S 3.18 x 114 mm (0.125 x 4.5 in) Thermistor Probe RTD  terminated in Spade Lugs   Buy Now
Fluke Hart 5642-B 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in bare wire   Buy Now
Fluke Hart 5642-D 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in 5-pin DIN for Tweener Thermometers   Buy Now
Fluke Hart 5642-G 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in gold pins   Buy Now
Fluke Hart 5642-I 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in INFO-CON for 1521 or 1522   Buy Now
Fluke Hart 5642-J 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in banana plugs   Buy Now
Fluke Hart 5642-L 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in mini spade lugs   Buy Now
Fluke Hart 5642-M 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in mini banana plugs   Buy Now
Fluke Hart 5642-P 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in INFO-CON for 1523 or 1524   Buy Now
Fluke Hart 5642-S 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in Spade Lugs   Buy Now
Fluke Hart 5643-B 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in bare wire   Buy Now
Fluke Hart 5643-D 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in 5-pin DIN for Tweener Thermometers   Buy Now
Fluke Hart 5643-G 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in gold pins   Buy Now
Fluke Hart 5643-I 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in INFO-CON for 1521 or 1522   Buy Now
Fluke Hart 5643-J 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in banana plugs   Buy Now
Fluke Hart 5643-L 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in mini spade lugs   Buy Now
Fluke Hart 5643-M 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in mini banana plugs   Buy Now
Fluke Hart 5643-P 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in INFO-CON for 1523 or 1524   Buy Now
Fluke Hart 5643-S 3.18 x 114 mm (0.125 x 4.5 in) Thermistor RTD Probe terminated in Spade Lugs   Buy Now
Fluke Hart 5644-B 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in bare wire   Buy Now
Fluke Hart 5644-D 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in 5-pin DIN for Tweener Thermometers   Buy Now
Fluke Hart 5644-G 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in gold pins   Buy Now
Fluke Hart 5644-I 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in INFO-CON for 1521 or 1522   Buy Now
Fluke Hart 5644-I-6FT 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in INFO-CON for 1521 or 1522 w/6ft of cable   Buy Now
Fluke Hart 5644-J 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in banana plugs   Buy Now
Fluke Hart 5644-L 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in mini spade lugs   Buy Now
Fluke Hart 5644-M 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in mini banana plugs   Buy Now
Fluke Hart 5644-P 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in INFO-CON for 1523 or 1524   Buy Now
Fluke Hart 5644-S 3.18 x 229 mm (0.125 x 9 in) Thermistor RTD Probe terminated in Spade Lugs   Buy Now

For your convenience the Probe Termination "X" has been incorporated in the above Model Numbers

Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), “P” (INFO-CON for 1523 or 1524), or “S” (spade lugs).

Fluke Hart Scientific 5640 5641 5642 5643 5644 RTD Temperature ProbeDetectors