Fluke Hart Scientific 5618B PRT Pt100 RTD Reference Temperature Probe Detectors
Fluke Hart Scientific 5618B Reference Pt100 RTD Platinum Resistance Temperature Detectors-Sensors
FLUKE
Fluke Hart Scientific 5618B PRT RTD Small Diameter (0.125") Platinum Temperature Resistance Detector with Excellent Stability

Fluke Hart Scientific 5618B Platinum Resistance RTD Temperature Detector/Sensors

Fluke Hart's 5618B RTD PRT temperature sensing element is manufactured using premium high-purity platinum. There is no other NIST-traceable reference temperature sensor that matches the accuracy and temperature range of Hart's 5618B for the same price. Hart's 5618B-12 is a 100 platinum resistance thermometer (PRT) with excellent short-term repeatability and comes with a NIST-traceable calibration certificate. 

Fluke Hart Scientific 5618B (0.125in. dia.)Pt 100 Platinum Resistance Temperature Probe/Detectors Datasheet

Fluke Hart Scientific 5618B Secondary PRT ~ RTD Platinum Industrial Standard Temperature Probe Detector-Fast Thermal Response

For secondary level performance with full ITS-90 calibration, Hart’s 5618B series RTDs PRTs are an excellent choice for critical temperature measurements. Featuring a 3.2 mm diameter (1/8 in) sheath, these industrial standards probes have reduced response time due to the low thermal mass design, without compromising precision. Hart's small diameter 5618A probe works well in many applications where immersion depth is limited. Larger diameter probes give more measurement error in short immersion depth applications because they conduct more heat between ambient and the sensor. 

Full NVLAP Accredited Calibration Report with each Hart 5618B RDT PRT Temperature Probe

With each probe you will receive a full NVLAP-accredited calibration report. On the report you’ll get the test data and the ITS-90 calibration coefficients that you can easily input into your Hart thermometer. If you are using a 1523 & 1524 Handheld Thermometer readout, we’ll program the coefficients directly into your INFO-CON connector. 

Hart's 5618B is also a great probe to use for calibrating your Hart 9132 or 9133 infrared calibrators. In fact, these IR black body heat sources were designed to be calibrated with this type of probe. Now you can calibrate these targets in your own lab! 

Fluke Hart 5618B Compatible with Fluke Hart Scientific Temperature Readouts

Use the 5618B with Hart’s 1560 Black Stack, 1529 Chub-E4, or 1502A Tweener thermometer readouts.  Each sensor comes with a manufacturer’s report of calibration. The report includes the expanded uncertainty (k=2) at seven calibration temperature points, ITS-90 calibration coefficients, and a temperature vs. resistance table presented in 1 °C increments.  Compare Hart's 5618B to other Secondary Reference PRTs. You’ll like its price, but you’ll love its performance. 


Hart 5618B PRT RTD Specifications
Temperature range  –200 °C to 500 °C
(–200 °C to 300 °C for 5618B-6-X) 
Nominal resistance at 0.01 °C  100
Temperature coefficient  0.003923 // °C nominal 
Calibrated Accuracy†[1]()k=2) ± 0.026 °C at –200 °C
± 0.066 °C at 0 °C
± 0.219 °C at 500 °C 
Drift  ± 0.1 °C when used periodically to 500 °C 
Hysteresis  Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points
Sheath material  316 SST 
Time Constant  Four seconds maximum for 63.2 % response to step change in water moving
at 3 fps
Thermal EMF  Less than 25 mV at 420 °C 
Size  5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in)
5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in))

†Includes calibration uncertainty and drift specification.  

 

Calibration Uncertainty
Temperature
Expanded
Uncertainty (k=2) 
–196 °C 
0.024 °C 
–38 °C 
0.011 °C 
0 °C 
0.010 °C 
200 °C 
0.018 °C 
420 °C‡ 
0.029 °
Note: Laboratories may periodically reevaluate their uncertainties. Calibration uncertainties depend on the calibration process, the standards used, and the instrument performance.
Please e-mail
ATEquip.com for Product Availabililty or a Price and Delivery Quotation. 858-756-8742
Fluke Hart 5618B ORDERING INFORMATION Data sheet
Model
Description
Featured Price
Fluke Hart 5618B-12-A Secondary Reference PRT RTD,100 (0.250 x 11.75 in),
–200 to 420 °C  terminated in INFO-CON for 914X

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-B Secondary Reference PRT RTD, 100(0.250 x 11.75 in),
–200 to 420 °C terminated in bare wire

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-D Secondary Reference PRT RTD,100(0.250 x 11.75 in),
–200 to 420 °C  terminated in 5-pin DIN for Tweener Thermometers

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-G Secondary Reference PRT RTD,100 (0.250 x 11.75 in),
–200 to 420 °C  terminated in gold pins

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-I Secondary Reference PRT RTD, 100(0.250 x 11.75 in),
–200 to 420 °C  terminated in (INFO-CON for 1521 or 1522)

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-J Secondary Reference PRT RTD,100 (0.250 x 11.75 in),
–200 to 420 °C terminated in banana plugs

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-L Secondary Reference PRT RTD, 100(0.250 x 11.75 in),
–200 to 420 °C  terminated in mini spade lugs

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-M Secondary Reference PRT RTD,100 (0.250 x 11.75 in),
–200 to 420 °C terminated in mini banana plugs

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-P Secondary Reference PRT RTD, 100(0.250 x 11.75 in),
–200 to 420 °C  terminated in INFO-CON for 1523 or 1524

$1015.00

$964.00 Buy Now
Fluke Hart 5618B-12-S Secondary Reference PRT RTD, 100, (0.250 x 11.75 in),
–200 to 420 °C terminated in spade lugs

$1015.00

$964.00 Buy Now