cart
atequip logo
Fluke Hart Scientific 5608 5609 Secondary Reference PRT RTD Temperature Detectors

Main Menu
 
New Product
Products
70KV High Voltage Meter
Fluke Hart Scientific 5608 & 5609 PRT Pt100 RTD Reference Temperature Detectors
Fluke Hart Scientific 5608 and 5609 Reference Pt100 RTD Platinum Resistance Temperature Detectors-Sensors
FLUKE
Fluke Hart Scientific 5608 & 5609 PRT RTD Seconday Reference Temperature Resistance Detector Using Pt 100 Sensors for RTDs & PRTs

Fluke Hart Scientific 5608 5609 Platinum Resistance RTD Temperature Detector/Sensors

Both of the Fluke Hart Scientific5608 & 5609 Platinum Resistance Temperature Sensor/Porbes RTDs are designed using Inconel™ sheaths and are made using a special manufacturing process, giving them greater precision over a wide temperature range. The sensors for these Pt 100 and Pt 25 probes are reference-grade platinum and features four-wire connections for less noisy measurements and reduction of the effect of lead wire resistance than two-wire counterparts.

Fluke Hart Scientific 5608 and 5609 Pt 100 & Pt 25 Platinum Resistance Temperature Probe/Detectors Datasheet

Fluke Hart Scientific 5608 and 5609 Secondary PRT ~ RTD Platinum Reference Detector-Thermometers

The Fluke Hart 5609 is a very stable thermometer from –200 °C to 670 °C and under goes ridgit calibration procedures. Look no further than our 5609 Secondary Reference PRT RTD. Its short-term stability at the triple point of water is only ± 7 mK and its one-quarter inch (6.23mm) diameter lets you get accurate measurements in only 100 mm of immersion. The 5608 is also a ±  7 mK probe at the triple point of water, and its one-eighth inch (3.18 mm) diameter gets you accurate measurements from –200 °C to 500 °C with only 80mm (3.1 in) of immersion. With multiple sheath length options avaiplable on both of these resistance temperature sensor/probes, you can find the dimensions that are just right for your specific application. 

Hart 5608 & 5609 Platinum RTDs offer Variable Insertion Lengths

The 5608 comes with a one-eighth inch (3.18 mm) diameter sheath in lengths of 9 inches or 12 inches. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm. 

Hart 5608 & 5609 RTDs offer ImprovedThermal Response Times

When looking for improved Thermal response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by thermal conduction attributed to the diameter of the stem rather than the length of the stem. 

Improved Precisi0on Incorporated in the Design of the Hart 5608 & 5609 RTD Temperature Sensors

Both of the 5608 & 5609 RTD temperature probes utilize the exclusive thermal properties of Inconel™ sheaths and are made using a special manufacturing process, there by giving both the 5608 & 5609 RTds greater precision over a wider temperature range. The RTD Temperature sensors for these probes are constructed using reference-grade platinum and feature four-wire connections which offer less noisy measurements and reduces the influence of lead wire resistance than two-wire counterpart designs. 

NVLAP Accredited Calibration Available for the Hart 5608 and 5609 RTD Platinum Resistance Temperature Detector/|Sensors

The Hart 5608 & 5609 RTD probe/sensors come with a certificate of compliance to ensure the meet their specifications. If you’d like, you can also order a NVLAP-accredited calibration from our laboratory, lab code 200348-0. On the report of calibration, you’ll get the test data and the ITS90 calibration coefficients that you can easily input into any Hart thermometer. If you order your probe with an INFO-CON connector, we’ll program the coefficients directly into your connector, which loads the coefficients for you when you plug it into our 1522 Handheld Thermometer.

Hart 5608 & 5609 PRT RTD Specifications
Temperature range  5608: –200 °C to 500 °C
5609: –200 °C to 670 °C 
Nominal resistance at 0.01 °C  100±  0.5
Temperature coefficient  0.0039250 //°C 
Relative Accuracy[1]  ± 0.007 °C at –200 °C
± 0.008 °C at 0 °C
± 0.020 °C at 420 °C
± 0.027 °C at 660 °C 
Short-term repeatability[2]  ±  0.007 °C at 0.010 °C
±  0.013 °C at max temp 
Drift[3]  ±  0.01 °C at 0.010 °C
±  0.02 °C at max temp 
Hysteresis  ±  0.01 °C maximum 
Sensor length  30 mm ±  5 mm (1.2 in ±  0.2 in) 
Sensor location  3 mm ±  1 mm from tip (0.1 in ±  0.1 in) 
Sheath material  Inconel™ 600 
Minimum insulation resistance  5608: 500 Mat 23 °C, 20 Mat 500 °C
5609: 500 Mat 23 °C, 10 Mat 670 °C 
Transition junction temperature range[4]  –50 ºC to 200 °C 
Minimum immersion length[5]
(<5 mK error) 
5608: 80 mm (3.1 in)
5609: 100 mm (3.9 in) 
Maximum immersion length  305 mm (12 in) 
Response time[5]  5608: 9 seconds typical
5609: 12 seconds typical 
Self heating (in 0 °C bath)  5608: 75 mW/°C
5609: 50 mW/°C 
Lead-wire cable type  Teflon,™ 24 AWG 
Lead-wire length  1.8 m (6 ft) 
Lead-wire temperature range  –50 °C to 250 °C 

1]Includes short-term repeatability and 100 hr drift. Calibration will add additional uncertainties. 

[2]Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2) 

[3]After 100 hours at max temp, 95 % confidence (k=2) 

[4]Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch. 

[5]Per ASTM E 644 

Calibration Uncertainty for optional NVLAP-accredited† calibration 
Temperature
Expanded
Uncertainty (k=2) 
–200 °C 
0.025 °C 
–100 °C 
0.025 °C 
–40 °C 
0.025 °C 
0 °C 
0.025 °C 
156 °C 
0.025 °C 
230 °C 
0.030 °C 
420 °C 
0.045 °C 
660 °C 
0.050 °C 
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties.  †Lab code 200348-0 
Please e-mail
ATEquip.com for Product Availabililty or a Price and Delivery Quotation. 858-756-8742
Fluke Hart 5608 5609 ORDERING INFORMATION Data sheet
Model
Description
Featured Price

Fluke Hart 5608-9-A

Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in INFO-CON for 914X

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-B Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in bare wire

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-D Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in 5-pin DIN for Tweener Thermometers

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-G Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in gold pins

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-I Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in (INFO-CON for 1521 or 1522)

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-J Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in banana plugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-L Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in mini spade lugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-M Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in mini banana plugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-P Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in INFO-CON for 1523 or 1524

$605.00

$574.00 Buy Now
Fluke Hart 5608-9-S Secondary Reference PRT RTD, 9 in x 1/8 in, –200 to 500 °C terminated in spade lugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-A Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in INFO-CON for 914X

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-B Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in bare wire

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-D Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in 5-pin DIN for Tweener Thermometers

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-G Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in gold pins

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-I Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in (INFO-CON for 1521 or 1522)

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-J Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in banana plugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-L Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in mini spade lugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-M Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in mini banana plugs

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-P Secondary Reference PRT RTD, 12 in x 1/8 in, –200 to 500 °C terminated in INFO-CON for 1523 or 1524

$605.00

$574.00 Buy Now
Fluke Hart 5608-12-S Secondary Reference PRT RTD, 100 ohms, 12 in x 1/8 in, –200 to 670  °C terminated in spade lugs

$605.00

$574.00 Buy Now
Fluke Hart 5609-12-A Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in INFO-CON for 914X

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-B Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in bare wire

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-D Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in 5-pin DIN for Tweener Thermometers

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-G Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in gold pins

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-I Secondary Reference PRT RTD, 12 in x 1/4in, –200 to 670 °C terminated in (INFO-CON for 1521 or 1522)

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-J Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in banana plugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-L Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in mini spade lugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-M Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in mini banana plugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-P Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in INFO-CON for 1523 or 1524

$795.00

$755.00 Buy Now
Fluke Hart 5609-12-S Secondary Reference PRT RTD, 12 in x 1/4 in, –200 to 670 °C terminated in spade lugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-15-A Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in INFO-CON for 914X

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-B Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in bare wire

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-D Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in 5-pin DIN for Tweener Thermometers

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-G Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in gold pins

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-I Secondary Reference PRT RTD, 15 in x 1/4in, –200 to 670 °C terminated in (INFO-CON for 1521 or 1522)

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-J Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in banana plugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-L Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in mini spade lugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-M Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in mini banana plugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-P Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in INFO-CON for 1523 or 1524

$840.00

$798.00 Buy Now
Fluke Hart 5609-15-S Secondary Reference PRT RTD, 15 in x 1/4 in, –200 to 670 °C terminated in spade lugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-20-A Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in INFO-CON for 914X

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-B Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in bare wire

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-D Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in 5-pin DIN for Tweener Thermometers

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-G Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in gold pins

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-I Secondary Reference PRT RTD, 20 in x 1/4in, –200 to 670 °C terminated in (INFO-CON for 1521 or 1522)

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-J Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in banana plugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-L Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in mini spade lugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-M Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in mini banana plugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-P Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in INFO-CON for 1523 or 1524

$995.00

$945.00 Buy Now
Fluke Hart 5609-20-S Secondary Reference PRT RTD, 20 in x 1/4 in, –200 to 670 °C terminated in spade lugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-300-A Secondary Reference PRT RTD, 300mm x 6mm –200 to 670 °C terminated in INFO-CON for 914X

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-B Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in bare wire

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-D Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in 5-pin DIN for Tweener Thermometers

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-G Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in gold pins

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-I Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in (INFO-CON for 1521 or 1522)

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-J Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in banana plugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-L Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in mini spade lugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-M Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in mini banana plugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-P Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in INFO-CON for 1523 or 1524

$795.00

$755.00 Buy Now
Fluke Hart 5609-300-S Secondary Reference PRT RTD, 300mm x 6mm, –200 to 670 °C terminated in spade lugs

$795.00

$755.00 Buy Now
Fluke Hart 5609-400-A Secondary Reference PRT RTD, 400mm x 6mm –200 to 670 °C terminated in INFO-CON for 914X

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-B Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in bare wire

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-D Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in 5-pin DIN for Tweener Thermometers

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-G Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in gold pins

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-I Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in (INFO-CON for 1521 or 1522)

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-J Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in banana plugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-L Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in mini spade lugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-M Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in mini banana plugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-P Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in INFO-CON for 1523 or 1524

$840.00

$798.00 Buy Now
Fluke Hart 5609-400-S Secondary Reference PRT RTD, 400mm x 6mm, –200 to 670 °C terminated in spade lugs

$840.00

$798.00 Buy Now
Fluke Hart 5609-500-A Secondary Reference PRT RTD, 500mm x 6mm –200 to 670 °C terminated in INFO-CON for 914X

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-B Secondary Reference PRT RTD,500mm x 6mm, –200 to 670 °C terminated in bare wire

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-D Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in 5-pin DIN for Tweener Thermometers

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-G Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in gold pins

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-I Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in (INFO-CON for 1521 or 1522)

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-J Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in banana plugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-L Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in mini spade lugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-M Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in mini banana plugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-P Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in INFO-CON for 1523 or 1524

$995.00

$945.00 Buy Now
Fluke Hart 5609-500-S Secondary Reference PRT RTD, 500mm x 6mm, –200 to 670 °C terminated in spade lugs

$995.00

$945.00 Buy Now
Fluke Hart 5609-9BND Secondary Reference PRT, 15 in x 1/4 in, 9 in bend,
–200 °C to 670 °C, (optional calibration: 1924-4-7 only)
$970.00
$919.00 Buy Now
Fluke Hart 2601 Plastic RTD Case for Models ending in -9, -12 & -300
~
$95.00
Buy Now
Fluke Hart 2609 Plastic RTD Case for Models ending in 15, -20, -400, -500
~
$155.00
Buy Now

Probe P/N Termination Specify X: e.g. 5609-6-X

Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), “P” (INFO-CON for 1523 or 1524), or “S” (spade lugs).

 

Fluke Hart Scientific 5608 & 5609 PRT Pt100 RTD Reference Temperature Detectors