Fluke Hart Scientific 5606 & 5607 Full Immersion PRTs Thermometers

Main Menu
 
New Product
sample product 2
Products
70KV High Voltage Meter
Fluke Hart Scientific Series 5606 & 5607 Full Immersion PRTs Thermometer
Fluke Hart Scientific 5606 & 5607 RTD Full Immersion PRTs Thermometers for Freezers, Autoclaves and Furnsces
FLUKE
Fluke Hart Scientific 5606 & 5607 are Accurate Thermometer Probes that Measure from -200 to 450 °C

 

Fluke Hart Scientific 5606 and 5607 "Full Immersion PRTs" Thermometers Data sheet

Fluke Hart Scientific 5606 and 5607 PRT Thermometers are Designed to Perform "Full IMmersion in Extreme Environments

The Fluke Hart 5606 and 5607 Fully Immersionable PRTs are designed to perform in extreme environments where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe. (“Immersion” in this case simply means exposure to temperatures other than ambient and does not necessarily refer to the medium to which the PRT and its components are subjected.)

Hart 5606 & 5607 "Full Immerison" Thermometer Applications

Applications where “full immersion” of probe, transition junction, and lead wire is required can include calibration or validation of sensors used in laboratory or bio freezers, walk-in refrigerators, autoclaves, ovens, stability test chambers, furnaces or incubators. Other applications might include IQ/OQ/PQ qualification procedures, temperature mapping, or data logging in temperature controlled spaces or environmental chambers.

Fluke Hart 5606 Immersion PRT Thermometer Operates from –200°C to 160°C

Hart's 5606 PRT is just two inches (50 mm) in length with a sheath diameter of 1/8 inch (3.1 mm). Since the Hart 5606 can be fully immersed over its entire temperature range, you don’t have to worry about calculating minimum immersion depth—immerse the entire probe, transition junction, and lead wires, in either non-corrosive liquids or dry mediums ranging from –200 °C to 160 °C. The 100 Ohm precision sensing element (alpha = 0.00385) is specially constructed to prevent the ingress of moisture while achieving calibration accuracies as good as ± 0.05 °C. You get both accuracy and flexibility built into a small, durable package.

Harts' 5606 PRT Thermometer is Designed to Prevent Accuracy Degration via Moisture Contamination

The lead wires of the Hart 5606 PRT are made of single-conductor enameled copper wire which prevents moisture from wicking to the sensing element as it would if a more common, stranded lead wire were used. The diameter of the lead wire is no greater than 0.2 mm, making it easy to run lead wires through a freezer door to your readout or transmitter with effectively zero energy loss. Hart's 5606 PRT has been proven in common heat transfer fluids such as silicone oil, mineral oil, ethanol, and even liquid nitrogen with no degradation of the transition junction seal or lead wire insulation.

Fluke Hart 5607 Dry Medium PRT Thermometer Operates from 0°C to 450°C

Are you performing calibrations or verifying the accuracy of sensors used in ovens or furnaces? Hart's 5607 PRT Thermometer has been designed specifically for your application. Intended to be used in dry mediums only, the Fluke Hart 5607 PRT can be fully immersed over a temperature range of 0 °C to 450 °C. There isn't’t another PRT on the market that can be fully immersed over this range and remain as stable and accurate (± 0.055 °C). The lead wire of Hart's 5607 is shielded with braided stainless steel and connected to the transition junction with a strain relief spring. If you need longer lead wire than the standard length, call one of our Application Specialists at ATEquip today for a free quote. They can also help you determine which readout and probe termination are best suited for your application or help you select the right calibration for your probe.

Specifications
5606
5607

Temperature range

-200 °C to 160 °C

0 °C to 450 °C

Nominal resistance at 0.01 °C

100Ω ± 0.1Ω

Temperature coefficient

0.00385 Ω/Ω/°C nominal

Accuracy[1]
± 0.04 °C at 0.01 °C
± 0.06 °C at 160 °C
± 0.04 °C at 0.01 °C
± 0.07 °C at 450 °C
Short-term repeatability[2]t
± 0.03 °C at 0.01 °C
± 0.04 °C at 160 °C
± 0.020 °C at 0.01 °C
± 0.035 °C at 450 °C
Drift[3]
± 0.03 °C at 0.01 °C
± 0.04 °C at 160 °C
± 0.02 °C at 0.01 °C
± 0.04 °C at 450 °C
Hysteresis
± 0.015 °C
Sheath length
50mm ±5 mm (2 in ± 0.2 in)
40 mm ± 5 mm(1.6 in ± 0.2 in)
Sheath diameter
40 mm ± 5 mm (1.6 in ± 0.2 in)
Sheath material
316 SST
Inconel® 600
Transition junction temperature range[4]
-200 °C to 160 °C
0 °C to 450 °C

Transition junction dimensions

No transition
35 mm x 7 mm (1.4 in x 0.3 in)
Sensor length
30 mm ± 3mm (1.2 in ±0.1 in)

Sensor location

3 mm ± 1 mm from tip (1.2 in ± 0.04 in)

Minimum insulation resistancet
20 MΩ at 23 °C
100 MΩ at 23 °C

Minimum immersion length

Full immersion)

Maximum immersion depth in liquid medium
Full immersion
Use SST or glass tube to protect transition junction
Maximum immersion depth in dry medium
Full immersion
Response time[5]
12 seconds typical
9 seconds typical
Self heating (in 0 °C bath)
± 0.003 °C
Lead-wire cable type
Lead-wire cable type
SST over-braid
Lead-wire temperature range
160 °C
450 °C

Calibration

Calibration not included. NVLAP accredited calibration available. See ordering information
[1] Includes calibration and 100 hr drift (k = 2).
[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k = 2).
[3] After 100 hours at max temp, 95 % confidence (k = 2).
[4] Temperatures outside this range will cause irreparable damage.
[5] Per ASTM E 644.
5606 Calibration Uncertaintly
Temperature

1924 Calibration Uncertainty†

Tolerance w/out Calibration‡

-197 °C

0.03 °C

0.4 °C

-38 °C

0.03 °C

0.2 °C

0 °C

0.03 °C

0.1 °C

100 °C

0.045 °C

0.3 °C

157 °C

0.05 °C

0.4 °C

5606 Calibration Uncertaintly

0 °C

0.03 °C

0.1 °C

157 °C

0.05 °C

0.2 °C

232 °C

0.05 °C

0.3 °C

450 °C

0.055 °C

0.5 °C

† Lab code 200348-0
‡ Each PRT includes a certificate with a measured R0 value.
An uncalibrated 5606 or 5607 meets ASTM E 1137 Grade A Classification of Tolerances. Use the coefficients below to achieve the tolerances listed in the “No Calibration” column or calculate the Grade A tolerance using the following formula: Grade A = ± [0.13 + 0.0017|t|]°C where: |t| = value of temperature (°C) without regard to sign. See ASTM E 1137.
R0: Enter the R0 value provided
A: 3.9083 x 10–3
B: –5.775 x 10–7
C: –4.183 x 10–4
When ordering the Fluke Hart Scientific 5606 and 5607 "Full Immersion PRTs" Thermometers, it is not necessary to include "Ex" in the model number as both models are Intrinsically Safe (Ex).
NIST Traceable Calibration Optionally Available

Fluke Hart Scientific 5606 & 5607 Full Immersion PRTs Thermometers

ORDERING INFORMATION Data Sheet

Model
Description
Introductory Price
Hart Scientific 5606-50-A Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (INFO-CON for 914X)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-B Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (bare wire)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-D Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: 5-pin DIN for Tweener Thermometers)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-G Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (gold pins)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-I Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (INFO-CON for 1521 or 1522)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-J Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (banana plugs)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-L Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (mini spade lugs)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-M Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (mini banana plugs)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-P Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (INFO-CON for 1523 or 1524)

$420.00

$399.00 Buy Now
Hart Scientific 5606-50-S Fluke Hart 5606 Immersion PRT, 50mm, -200 °C to 160 °C : Termination: (spade lugs)

$420.00

$399.00 Buy Now
Hart Scientific 5607-75-A Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (INFO-CON for 914X)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-B Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (bare wire)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-D Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: 5-pin DIN for Tweener Thermometers)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-G Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (gold pins)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-I Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (INFO-CON for 1521 or 1522)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-J Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (banana plugs)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-L Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (mini spade lugs)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-M

Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (mini banana plugs)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-P Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (INFO-CON for 1523 or 1524)

$605.00

$595.00 Buy Now
Hart Scientific 5607-75-S Fluke Hart 5607 Hi-Temp Immersion PRT, 75mm, 0 °C to 450 °C Termination: (spade lugs)

$605.00

$595.00 Buy Now
1924-4-10 PRT Calibration, –200 to 157 °C, NVLAP-accredited‡ $00.00 $00.000 Buy Now
1924-5-10 PRT Calibration, –40 to 157 °C, NVLAP-accredited‡ $00.00 $00.000 Buy Now
1924-P PRT Calibration, 0 to 450 °C, NVLAP-accredited‡ $00.00 $00.000 Buy Now
1930-4-10 System Calibrated by Comparison, –200 to 157 °C, NVLAP-accredited‡ $00.00 $00.000 Buy Now
1930-5-10 System Calibrated by Comparison, –40 to 157 °C, NVLAP-accredited‡ $00.00 $00.000 Buy Now
1930-P System Calibrated by Comparison, 0 to 450 °C, NVLAP-accredited‡

$00.00 $00.000 Buy Now
Hart Scientific 2603 Case for both 5606 & 5607 "Full Immersion PRTs"

$.00

Buy Now
Please e-mail ATEquip.com for Product Availability or a Price and Delivery Quotation. Thank you.

858-756-8742 sales@ATEquip.com

Fluke Hart Scientific 5606 5607 Full Immersion PRTs Thermometer Readouts