Fluke Hart Scientific Series 1560 "Black Stack" Reference Thermometer Readouts
Fluke Hart Scientific 1560 Reference Thermomtry System for RTDs, PRTs, Thermocouples and Thermistor Sensors
FLUKE
Fluke Hart Scientific 1560 "Black Stack" Reference Thermometers Readouts for RTDs, PRTs, Thermocoulpes and Thermistor Sensor

Fluke Hart Scientific 1560 Thermometry System Thermometers

Fluke Hart's 1560 "Black Stack" Temperature Readouts are compatible with SPRTS, PRTs, RTDs, Thermistors and Thermocouples. Nothing about Hart's 1560 "Black Stack" implies or says ordinary. Traditionally, thermometers were square boxes configured to do one particular job—such as read a calibrated PRT. However, if you also wanted to measure thermistors, you had to buy another instrument that could do that specific task. Some thermometers can do multiple jobs, but they’re expensive, complex, and difficult to use. You’re paying for functions you don’t need and may never use. Hart's "Black Stack" thermomerter readouts solves these problems and more. Hart’s "Black Stack" thermometer has been on the market for five years and has established itself as one of the most versatile, cost-effective, accurate readouts in the world.

Fluke Hart Scientific 1560 Reference Thermometers Datasheet

Fluke Hart Scientific 1560 Versatile Thermometry Base Unit Temperature Readout

Hart's 1560 "Black Stack" Thermometry Base Unit can be any kind of thermometer you want it to be, and it works in three distinctive ways. It’s a reference thermometer with a  NIST traceable calibration; it’s an automated calibration system reading your reference probe and sensors you’re testing; or it’s a high-accuracy data acquisition system. And it does each of these functions better than any other thermometer currently on the market.

Hart's 1560 "Black Stack" Offers Eight Thermometry Modules to Create the Perfect Temperature Calibration System

Fluke's "Black Stack" Thermometry Calibration System consists of up to eight different modules that fit together to do any type of thermometry you choose. You can buy all of them, or any combination of them, and change the "Black Stack" and its functions anytime you want. Each module stacks behind the preceding one, and when you add a module, the Stack’s software automatically reconfigures itself to include all of the new functions supplied by that module. There’s nothing to take apart. No boards need to be installed. There’s no software to load, and nothing has to be calibrated. Just stack a new module onto the back of the previous modules and you’re ready to use the Black Stack and all of its remarkable features

Hart’s new Model 9935 Multi Channel LogWare makes the "Black Stack" an even more powerful data acq.isition tool. LogWare provides graphical and statistical analysis of each channel you’re measuring (up to 96 with the Black Stack). And with alarms that can be customized, delayed start times, and selectable logging intervals, LogWare turns the Black Stack into the most powerful temperature data acquisition tool on the market.

Hart's 1560 Black Stack Base Unit Provides System Power ~ Communication ~Software

Hart's Black Stack Themometry system starts with a base module. It consists of two parts: a display with the main processor and a power supply. The base module supplies power, communication management, and software coordination for all of the other modules. Fluke Hart's 1560 has the display, control buttons, and RS-232 port built-in. Each Hart 1560 Black Stack base module can handle eight thermometer modules stacked behind it with a maximum of 96 sensor inputs. The base module never needs calibration and performs its own diagnostic self-test each time it powers up. The thermometer characteristics of each base module are defined by the thermometry modules stacked behind it.

Nine Modules to Compliment Hart's 1560 "Black Stack" Thermometry System

There are nine thermometry modules: an SPRT module, a high-temp PRT module, a PRT scanner module, a standards thermistor module, two 1000-ohm PRT modules, a thermistor scanner module, a precision thermocouple module, and a thermocouple scanner module. Each module has its own processor and connects to the "Stack" on a proprietary digital bus. Each module retains its own calibration data and performs all analog measurement functions within the module.

Hart SPRT Module 2560

The SPRT module reads 25-ohm and 100-ohm four-wire RTDs, PRTs, and SPRTs with very high accuracy. It turns the Stack into a first-rate reference thermometer with an accuracy to ±0.005°C. Hart's SPRT module has two input channels for collection of data with two reference sensors, or you can do comparison calibrations of one sensor against a calibrated reference sensor. Temperature conversion features include direct resistance measurement, ITS-90, W(T90), IPTS-68, Callendar-Van Dusen, or an RTD polynomial conversion. The user-changeable default values for the CVD conversion fit the 100-ohm, 0.00385 ALPHA sensor described by IEC-751. The SPRT modules can be used one at a time or combined together in any combination for reading up to 16 different reference thermometers. If you stack an SPRT module with a scanner module, you can test multiple sensors against your reference. Unlike other competitive instruments, Hart's 2560 PRT Scanner Module operates with or without the two-channel SPRT module. If you can think of a way to use a reference thermometer, you can do it with the Stack.

Hart High-Temp PRT Module 2561

Hart's 2561 module reads 2.5-ohm and 0.25-ohm four-wire HTPRTs and RTDs. The complete resistance range covers up to 5-ohm sensors with applications as high as 1200°C. The temperature conversion features are the same as for the SPRT module, and like the SPRT module, the connectors are gold plated.

Hart PRT Scanner 2562

The Fluke Hart 2562 module reads eight channels of two-, three- or four-wire 100-ohm PRTs or RTDs. The accuracy is ±0.01°C at 0°C for calibration of industrial sensors. The common industrial RTD can be read with the default values in the CVD temperature conversion for fast setup of industrial applications, or you can enter individual probe constants for higher accuracy data acquisition.

Hart 2567 & 2568 1000-Ohm PRT Modules

For 1000-ohm PRTs, Hart's 2567 & 2568 Modules provide all the same great features as Hart's 2560 and 2562 Modules. The two-channel 2567 Module has a resistance range of 0 to 4000 ohms and is accurate to ±0.006°C at 0°C. Hart's 2568 Module reads up to eight 1000-ohm PRTs and at 0°C is accurate to ±0.01°C. Don’t use an ohmmeter or multimeter to read your 1000-ohm PRTs when you can use a Black Stack loaded with convenient temperature functions.

Fluke Hart 2563 Standards Thermistor Module

Special low-drift thermistors are becoming increasingly popular as reference probes in applications with modest temperature ranges up to 100°C. This2563 module has a temperature accuracy of ±0.0013°C at 0°C with a resolution of 0.0001°C. Hart's 2563 Thermistor Module has two input channels. It displays direct resistance in ohms or converts directly to a temperature readout using either the Steinhart-Hart equation or a higher-order polynomial.

Hart 2564 Thermistor Scanner Module

Harts 2564 module is usable with any type of thermistor but has eight channels instead of the two channels found on the Standards Thermistor Module and operates with or without the Standards Thermistor Module. This module’s accuracy is ±0.0025°C at 0°C for all eight channels. The eight channels make the 2564 module an excellent data acquisition tool. It can be used in research work or for verification of biomedical equipment such as DNA sequencing apparatus.

Hart 2565 Precision Thermocouple Module

Hart's 2565 Precision Thermocouple Module reads any type of thermocouple, including type S platinum thermocouples and the new gold-platinum thermocouples for standard's work. This two-channel module has internal cold junction compensation, or you can use an external source for even greater accuracy. All the standard ANSI thermocouple types are preprogrammed; however, you can choose a conversion method and then enter the probe characteristics of your sensor, creating a system-calibrated channel. Hart's 2565 module accepts up to three calibration points for error adjustment in the individual sensor. A polynomial interpolation function calculates the points between your measurements. Type R, type S, and gold-platinum conversions accept complete polynomial calibration coefficients. Additionally, a thermocouple conversion function calculates temperature by interpolating from a table. You enter the temperature in degrees C and the corresponding voltage for your specific sensor from 1 to 10 temperatures. Interpolation is performed between the entered points.

Hart 2566 Thermocouple Scanner Module

Hart's 2566 TC Scanning Module has 12 channels and reads K, J, T, S, R, B, E, and N thermocouples. Each channel can be set to read a different type of thermocouple. All temperature readings are performed in exactly the same manner as with the 2565 module. The connectors on the scanner module are special dual connectors that accept both the common miniature and standard thermocouple connectors. If you want to use screw terminals, use the appropriately-sized connector with the hood removed.

Hart 1560 " Black Stack" Features Common to All Modules

Fluke Hart's 1560 Black Stack is an incredible thermometer. You buy only the modules you need for the work you are doing. If your work changes, simply order the modules with the functions you need and slip them onto the back of the Stack. Your thermometer changes its software, display, and method of operation to match the new functions you’ve added. Remember, you never have to open the case to add modules. There’s no software to load. It’s all automatic. Each module stores its own calibration internally, so you can add or change modules without recalibrating the whole stack. Module calibration is  digital and is performed manually through the base’s front panel or over the RS-232 link. If your lab has the capability, you can calibrate modules yourself. If not, send them to us with or without your base unit and we’ll recalibrate them.

Hart's 1560 Display Screen offers Graphics & Strip Chart Recorder Formats

Hart's 1560 LCD screen has multiple methods of displaying data, including a graphical strip chart recorder. The graphical capability of the Black Stack makes testing temperature stability easier than ever. Vertical scaling and graph resolution are automatic. The Stack has high-accuracy, two-channel capability or multi-channel functionality if you need it. Its memory stores the most recent 1000 readings, or you can send your data to your PC through the RS-232 port. Each data point is time and date stamped. An IEEE-488 port is optional. With Hart's Black Stack you can read data almost anyway you like—in ohms, millivolts, or temperature, according to your application and preference. Remember, this thermometer’s calibration is traceable to NIST. Its accuracy is as high as ±0.0013°C, depending on the module and sensor you’re using.

The new Fluke 1560 "Black Stack" Reference Thermometers from Fluke’s Hart Scientific division measure, graph, and record PRTs, thermocouples, and thermistors. These new thermometer readouts deliver high accuracy, wide measurement range, data logging, and trending, all in a handheld tool you can take anywhere. The Hart Scientific 1560 "Black Stack" lets you handle field applications, laboratory measurements, and data logging with ease. And with the dual channel measurement capabilities of the model 1524, you can do twice the work in half the time.

Fluke Hart Scientific 1560 "Black Stack" Reference Thermometers Provide High Acuracy

The Fluke 1523 single channel Reference Thermometer provides memory capacity to store up 25 readings. The Fluke 1524 is a two channel Reference Thermometer readout with memory for data logging up to 15,000 measurements with real-time clock for time and date stamps. Typical high accuracies are PRTs up to ± 0.011 °C, Thermocouples up to ± 0.24 °C, and Precision Thermistors Sensors up to ± 0.002 °C. You need accuracy for compliance, product yields, energy savings, and consistent results. The Fluke 1560 "Black Stack" uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from –10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep the Fluke 1560 "Black Stack" accuracy virtually insensitive to environmental temperature.

For a Complete Listing of Temperature Probe Sensors Compatible with the Hart Temperature Readouts Link to:

Fluke Hart Scientific Reference Standard PRTs RTDs Temperature Sensors

 

Please e-mail ATEquip.com for Product Availability or a Price and Delivery Quotation. 858-756-8742
Fluke Hart Scientific 1560 Thermometry System RESISTANCE MODULES
SPRT Module 2560
Input Ch.
Range
Basic Ohms Accuracy
Ohms Res.
Temp. Range
Equivalent Temp. Acc.
Temperature. Resolution.
Excitation Current
2
0Ω to 400Ω
±20 ppm of reading (0.0005Ω at 25Ω,
0.002Ω at 100Ω)
0.0001Ω
–260°C to 962°C
±0.005°C at 0°C
±0.007°C at 100°C
0.0001°C
1.0 mA,
1.4 mA
High-Temp PRT Module 2561
2
0Ω to 25 Ω

±50 ppm of reading
(0.00013Ω at 2.5Ω)

0.0001Ω
0°C to 1200°C

±0.013°C at 0°C
±0.018°C at 100°C

0.001°C

3.0 mA,
5.0 mA

PRT Scanner 2562
8
0Ω to 400Ω

±40 ppm of reading
(0.004Ω at 100Ω)

0.0001Ω

–200°C to 850°C

±0.01°C at 0°C
±0.014°C at 100°C

0.0001°C

1.0 mA,
1.4 mA

Standards Thermistor Module 2563
2
0Ω to 1M Ω

±50 ppm of reading
(0.5Ω at 10 KΩ)

0.1Ω

–60°C to 260°C

±0.0013°C at 0°C
±0.0015°C at 75°C

0.0001°C
2 mA,
10 mA
Thermistor Scanner Module 2564
8
0Ω to 1M Ω

±100 ppm of reading
(1Ω at 10 KΩ)

0.1Ω

–60°C to 260°C

±0.0025°C at 0°C
±0.003°C at 75°C

0.0001°C
2 mA,
10 mA
1000 PRT Module 2567
2
0Ω to 4K Ω

±25 ppm of reading
(0.025Ω at 1 KΩ)

0.001Ω

–260°C to 962°C

±0.006°C at 0°C
±0.009°C at 100°C

0.0001°C

0.1 mA,
0.05 mA

1000 PRT Scanner 2568
8
0Ω to4K Ω

±40 ppm of reading
(0.04Ω at 1 KΩ)

0.001Ω
–200°C to 850°C

±0.01°C at 0°C
±0.014°C at 100°C

0.0001°C

0.1 mA,
0.05 mA

Thermocouple Modules

 
Input Chanels
Millivolt Range
mV Res.
mV Accuracy
Temp. Acc. Ext. CJC
Temp. Acc. Int. CJC
Temp. Res.
 
2

–10 to 100 mV

0.0001 mV
±0.002 mV

±0.05°C

±0.1°C

0.001°C

Thermocouple Scanner 2566

 
12
–10 to 100 mV 0.0001 mV

±0.004 mV

±0.1°C

±0.3°C

0.001°C

ORDERING INFORMATION Data sheet
Model
Description
Introductory Price

Hart Scientific 1560

Fluke- Hart Black Stack Thermometry System Readout Base Unit

$3325.00

$3158.00 Buy Now
Hart Scientific 2560

SPRT Module, 25 and 100 , 2-channel

$2165.00

$2056.00 Buy Now
Hart Scientific 2561

High-Temp PRT Module, 0.25 to 5, 2-channel

$2480.00

$2356.00 Buy Now
Hart Scientific 2562 PRT Scanner Module, 8-Channel

$2600.00

$2470.00 Buy Now
Hart Scientific 2563

Standards Thermistor Module, 2-channel

$2365.00

$2246.00 Buy Now
Hart Scientific 2564

Thermistor Scanner Module, 8-channel

$2085.00

$1985.00 Buy Now
Hart Scientific 2565 Precision Thermocouple Module, 2-channel 

$3220.00

$3059.00 Buy Now
Hart Scientific 2566 Thermocouple Scanner Module, 12-channel

$2625.00

$2493.00 Buy Now
Hart Scientific 2567 SPRT Module, 1000 , 2-channel 

$2205.00

$2099.00 Buy Now
Hart Scientific 2568 PRT Scanner Module 8-Channels,1000

$2610.00

$2499.00 Buy Now
Hart Scientific 3560 Extended Communications Module

$1395.00

$1325.00 Buy Now
Fluke Hart 9535-S LogWare II, Multi Channel, Single User   $848.00 Buy Now
Fluke Hart 9535-M LogWare II, Multi Channel, Multi User   $1219.00 Buy Now
Fluke Hart 9302 Case (holds 1560 and up to five modules)    $415.00 Buy Now
1523 Fluke Hart Scientific Series 1560 "Black Stack" Reference Thermometer Readouts 1524