Fluke 700P05 |
Fluke 700P06 |
Fluke 700P07 |
Fluke 700P27 |
Fluke 700P07 |
Fluke 700P08 |
Fluke 700P09 |
Fluke 700P05 |
|
Gauge Pressure Module |
Gauge Pressure Module |
Gauge Pressure Module |
Fluke Gauge Pressure Modules ~ 700P05 ~ 700P06 ~ 700P07 ~ 700P27 ~700P08 ~ 700P09 ~ 700P05 ~700P06
|
|
| |
|
| |
Fluke Gauge Pressure Modules ~ 700P05 ~ 700P06 ~ 700P07 ~ 700P27 ~700P08 ~ 700P09 ~ 700P05 ~700P06
|
|
| Specifications: FluFFluke Pressure Modules 700P00 | 700P01 | 700P02 | 700P22 |700P03 |700P23 |700P04 | 700P24 |
| Range: |
30 to 1500psi, 207KpA to 10MpA |
Resolution |
0.001psi / 0.01kPA |
| Reference Uncertainty (23 ± 3° C) |
0.025% |
Total¹ Uncertainty 1 year |
0.050% |
| High Side Media² |
316 SS |
Low Side Media² |
N/A |
Note |
Total uncertainty, one year for temperature range 0° C + 50° C. Total uncertainty, 1.0% of full span for temperature range - 10° C to 0° C. Compensated temperature range is 15° C to 35° C. |
Note |
"Dry" indicates dry air or non-corrosive gas as compatible media. "316 SS" indicates media compatible with Type 316 Stainless Steel."C276" indicates media compatible with Hastelloy C276. |
|
Model |
Range/ Resolution |
Ref Uncertainty (23 ± 3)°C |
Total Uncertainty |
High Side Media |
Low Side Media |
Fit-Matl |
MAX Over Press (x-times normal) |
| Gauge |
(316 SS indicates media compatible with type 316 stainless Steel) (Total Uncertainty = Reference Uncertainty + Stability (1-yr.) + Temperature Uncertainty) DATA SHEET |
| FLUKE-700P05 |
30 psi/0.001 |
0.025 |
.050 |
316 SS |
N/A |
316 SS |
3x |
| FLUKE-700P06 |
100 psi /0.01 |
0.025 |
.050 |
316 SS |
N/A |
316 SS |
3x |
| FLUKE-700P27 |
300 psi/0.01 |
0.025 |
.050 |
316 SS |
N/A |
316 SS |
3x |
| FLUKE-700P07 |
500 psi/0.01 |
0.025 |
.050 |
316 SS |
N/A |
316 SS |
3x |
| FLUKE-700P08 |
1000 psi/0.1 |
0.025 |
.050 |
316 SSDry |
N/A |
316 SS |
3x |
| FLUKE-700P09 |
1500 psi/0.1 |
0.025 |
.050 |
316 SS |
N/A |
316 SS |
3x |
NOTE |
1. Metric adapter(s): 1/4" NPT female to male BSP/ISO 1/4-19, tapered thread, included with all
modules except P29, P30, and P31.
2. NIST traceable Calibration Certificate with test data supplied with each module.
3. Maximum Overpressure specification includes common mode pressure. |
|
NIST Traceable Calibration Certificates
To assist our customers in satisfying ISO-9001:2000, section 8.2, certified monitor and measurement calibration requirements, ATEQUIP.com can supply for all of the Fluke products, certified NIST traceable calibration certificates from an ANSI/NCSL Z540-1-1994 compliant-accredited/ ISO 17025 accredited calibration laboratory. Please contact us directly for information on your specific test equipment interest. |
|
| |
Gauge Pressure Module |
Gauge Pressure Module |
Gauge Pressure Module |
Gauge Pressure Module |
Fluke 700P05 |
Fluke 700P06 |
Fluke 700P07 |
Fluke 700P27 |
Fluke 700P07 |
Fluke 700P08 |
Fluke 700P09 |
Fluke 700P05 |
Fluke Gauge Pressure Modules ~ 700P05 ~ 700P06 ~ 700P07 ~ 700P27 ~700P08 ~ 700P09 ~ 700P05 ~700P06
|
|
|
|
|
|
|
 |
|