AMPTEC 620LK Aircraft Bonding Tester ~ Bonding Meter ~ Low Resistance Bonding Ohm Meter 620LK
|
 
|
|
AMPTEC 620LK Bond Tester Low Resistance Bonding Ohm Meter~ Explosive Safety Bonding Meter 
Bonding Meter for Testing Bonding Integrity on Aircraft, Missiles, Helicopers, Ships and Squibs
Derived from the USAF's AMPTEC 620LK-B Bonding Ohm Meter, the brand new AMPTEC 620LK Low Resistance Ohm Meter is an intrinsically Safe Bonding Milliohmmeter that measures even lower bond resistance levels with even better resolution and better accuracy. This Bonding Tester was designed originally for measuring very low resistance bonds that are less than ½ milliohm (on the Lockheed Martin F-35 Tiger Shark). The AMPTEC 620LK Bonding Ohm Meter's failsafe constant current source operates at ten times the level (100 mA vs 10 mA) of the AMPTEC 620LK-B Bonding Ohmmeter. The higher current level provides the AMPTEC 620LK with rock solid accurate readings below 1/2 or 0.5 milliohms with 0.01 milliohm resolution and a very high 0.1 milliohm accuracy . |
AMPTEC 620LK Aircraft Bonding Tester Automatically Locks-On to Low Resistance Bond Measurement ~ Holds Reading for 10 Seconds
620LK Low Resistance Bonding Ohm Meter makes Bonding Testing Easy and Safe
Amptec's Bonding Tester 620LK with its "Auto-Lock" feature automatically "Locks-On" & holds (displays) the lowest ohm bond measurement for 10 seconds then automatically resets. The intelligent AMPTEC 620LK's "Auto-locks", once continuity is established, locks onto the lowest resistance (bond) measurement automatically. This allows the operator to focus on proper Kelvin probe placement on the bonding surface(i.e. aircraft) without having to look at the meter while measuring, no range changes to deal with, no zeroing of the test leads. No erroneous readings, only when continuity is made, does it continuously sample measurements and lock in the lowest resistance reading and holds/displays it for 10 seconds (display backlight also comes on), then automatically resets (or manually select the front panel "Auto Measure Reset" switch to start over)  |
AMPTEC 620LK Intrinsically Explosive Safe Bonding Tester Low Resistance Ohm Meter 
Amptec's 620SL Low Resistance Explosive Safety Bonding Tester Ohm Meter is a portable Intrinsically Safe Explosive Safety Digital Milli-Ohm Meter. It was specifically designed (and UK Ministry of Defense EEX Approved) for ultra-safe resistance testing around fueling depots (flammable vapours present), Aircraft bonds/connections, refineries and explosive devices (i.e. squibs, igniters, flares, detonators, munitions, warheads) in volatile and explosive atmospheres. The AMPTEC620LK Bonding Tester complies with the EU ATEX Directive and is Intrinsic Safety Standard (Eex-ib-IIc-T4) compliant and certified under the ATEX Laboratory Certificate # SIRA03ATEX2076. Amptec's 620LK is Intrinsically Safe certified and can be safely used and "located where flammable gases and vapours of groups IIA, IIB, and IIC are present". The620LK Ohmmeter is only certified for use in ambient temperatures in the range of -20°C and +40°C and should not be used outside this temparature range. The AMPTEC620LK Safety Ohmmeter is also: EMC tested in accordance with British Defence Standard 59-41 and British Defence Standards 66-31, 07-85 and 05-34 (-40° Cold temperature, Damp Heat +°70C, Humidity and Altitude tests) compliant. The620LK Ohmmeter provides a reliable and safe means of measuring resistance in explosive and volatile atmospheres.
CERTIFIED MIL STD 810 METHOD 511 EXPLOSIVE AND VOLATILE ATMOSPHERE COMPLIANT~Safe Use in Fuel-Air Mixtures
Independent Certification - Environmental Test Laboratory in Los Angeles, CA - While fully operational, the AMPTEC 620LK Explosive Safety Bond Meter's test leads were successfully shorted then "opened" 400 times in the "saturated" explosive atmospheric fuel air mixture (Per MIL STD 810 Method 511 Rev F. "Explosive Atmospheres"). Independent Certification tests were conducted at Stork Garwood Laboratories, report number ENV8655SC, Rev:1.
It was shown to be fully MIL STD 810 Method 511 Rev F. "Explosive and Volatile Atmospheres" compliant @ +50°C. This means the AMPTEC 620LK Safety Bond Milliohmmeter when making contact with the item under test ( aircrfat chassis, fuel tank etc) does not produce sparks with minimal kinetic energy levels (not hazardous, will not ignite jet fuel or other volatile hydrocarbons). |
Intrinsically Safe Ohmmeter - EeX-ib-IIC-T4 British Defense Standard Compliant
The620LK circuitry has been independently laboratory certified as EEx "Intrinsically Safe" more than just safe in the unlikely event of a worst case component failure. The AMPTEC620LK Explosive Safety Ohmmeter output current limiting is still in effect, regardless of component failure by total design insite and compliance to the International Safety Standard of EeX-ib-IIC-T4.
MIL STD 810, Method 511, rev F "Explosive and Volatile Atmosphere" Laboratory Tested
The AMPTEC620LK Explosive Safety Ohmmeter has been independently laboratory certified as MIL STD 810, Method 511 (revision F) Explosive and Volatile Atmosphere compliant up to +50°C. The AMPTEC620LK Safety Ohmmeter was remotely operated in an explosive atmospheric chamber ( Air fuel mixed with highly volatile hexane ). While fully operational, the AMPTEC 620LK test lead contacts were successfully shorted then and disconnected 400 times in the explosive atmospheric fuel air mixture and shown to be fully compliant @ +50°C. A copy of the test report is available (620LK MIL STD 810_511 test ) .
U.S. NAVY Ordnance Safety Board ( Indianhead MD) Approved - For use on Evolved Sea Sparrow Missile Squibs (ESSM )
Amptec 620LK Bonding Meter Compared to Avtron T477W Bonding Meter
|
|
|
| Resolution |
10uΩ/200.00mΩ Range |
0.1mΩ(100uΩ)/200mΩRange |
| Test Current |
100mA DC |
200mA AC |
| Display LCD |
19999 Count (41/2) |
1999 Count (31/2) |
| Accuracy |
0.05% |
1% |
| Hold Low Reading |
Yes |
No |
| Test Leads |
4-Wire Spring Loaded Probes |
4-Wire Spring Loaded Probes |
| Intrinsically Safe |
Yes |
Yes |
| Price |
~$5000.00+ |
~$10,000.00- |
|
|
AMPTEC 620LK Igniter Tester-Ohmmeter Features:
4 ½ digit resolution, automatic ranging from 000.01 milliohms to 2.0 Ohms Full Scale
Enhanced Designed based upon the USAF Bonding Meter (USAF's AMPTEC 620LKB Bond Meter) - ideal replacement for obsolete, aging and over-priced 3 ½ digit AC Bonding Meters. As a ruggedized milliohmmeter The AMPTEC 620LK offers high accuracy (DC - better than 0.1 milliohm), 4 ½ digit resolution, 0.01 milliohm resolution with "No Warm-up" required its ready to use when turned on.
High Accuracy - 4 Wire Kelvin Milli-Ohmmeter with 0.1 milliohm basic accuracy from 0° to 40°C
Instant "ON", "No Waiting for a Warm-up Period", it's ready to use immediately after being powered up - The solid state internal reference(s) used by the AMPTEC 620LK Bonding Milli-Ohmmeter make it ready to use the instant it's water-proof power switch turned "on".
All metal ( Faraday Cage) construction (front, back and all sides), textured powder coated aero aluminum (AL 5052 alloy), all connected to front panel chassis ground jack.
Separate battery compartment, operates on 4 ea "AA" Alkalines (Duracell Coppertops) or Optional Rechargeable "AA" (NiMH cells ), field replaceable batteries (anyone can change the batteries) without breaking the calibration seal. There is "No access to any electronics inside the unit's battery compartment". It's also water-tight (gasket sealed compartment) and is corrosive resistant Per MIL PRF 28800D to any alkaline battery leakage or any chemical corrosion.
Ruggedized use -Silicone rubber boot covers on all switches protects the instrument against saltwater spray, rain and dust. 
|
|
| |
AMPTEC 620LK Bonding Ohmmeter Commercial Package also includes:
1) Protective padded carrying case,
2) 4-Wire Kelvin Handheld Probes (OP630-403 Mini-probes),
3) Operator/maintenance manual 4) U.S.A. N.I.S.T Traceable Calibration Certificate - MIL STD 130 Marking and MIL STD 129P packaging is optionally available. The AMPTEC 620LK Low Ohm Bond Meter is the ideal replacement for Aircraft Equipment Maintenance Team's to modernize their inventory getting away from of old heavy bonding ohmmeters that have been in use since the 1970's. |
Battery Option "NiMH"
The AMPTEC 620LK Bonding ohmmeter normally comes with 4 ea. disposible AA Alkaline batteries (ie Duracell coppertop), and battery life with disposible batteries depends on the usage (typically several weeks of use). The Option "NiMH" can typically operate for years of normal use on a standard set of 4 "AA" rechargable batteries (Rechargeable NiMH - Duracell, Energizer etc). With the battery compartment separate from any internal electronics, the user can change the batteries and not effect the instrument's calibration. The battery compartment cover is gasket backed to provide a water tight seal. The battery compartment is also MIL PRF 28800D compliant to be protected against any battery corrosion ( leaking alkaline material). 
|
|
620LK Easy to Calibrate "No Covers to Remove"
In addition, once the tamper resistant calibration sticker is removed from the AMPTEC 620LK Bonding Milli-Ohmmeter's rear panel, its easy to get to the unit's two calibration access holes and it's a breeeze to calibrate. There are "No Covers" to remove, the PMEL or calibration facility simply connects the 620LK to the proper Primary Resistance Standard and has two simple adjustments to make (Fullscale@100 milliohms and 10% of scale@1.00 milliohm). Calibration hole plugs are also included (inside carrying case pocket) if the AMPTEC 620LK Bonding Milliohmmeter user desires to use them.
|
|
620LK Optional 4 Wire Kelvin Pistol Grip Probes
The AMPTEC 620LK Bonding Ohmmeter Commercial package includes: Padded Carrying Case, Manual, Calibration Certificate and a set of 4 Wire Kelvin Handheld Probes or 4 Wire Kelvin Pistol Grip Probes ( Option PG-401). Each pistol grip probe has two spring loaded heavy duty rounded end tips. Sharped pointed tip based probes are also available upon request. All AMPTEC 630 series 4-Wire Kelvin test leads (i.e. banana jacks, handheld micro-probes etc.) are compatible with the AMPTEC 620LK 4-Wire Kelvin test lead connector. Bonding Milli-Ohmmeter as they ( 630ES, 630BN etc.) are all designed to connect to the same front panel ITT Canon Trident Connector |
| |
Please-mail ATEquip.com for AaMPTEC 620LK Availability or a Price and Delivery Quotation. Thank you. 
|
|
AMPTEC RESEARCH 620LK SPECIFICATIONS  |
Display: |
4½ digits (19999) LCD with back light. Display is visible in dim light ambient conditions. |
Temperature Coefficient: |
±.002% per °C (from 0°C to15°C and 35°C to 50°C) |
Temperature Range: |
0 ºC to 50 ºC (Operating) |
Measurement Leads: |
Two-wire configuration~Zero Adjustment for Lead Resistance |
Overload Indication: |
Display Flashes |
Maximum Input: |
250V DC or peak AC without damage (Into Ohmmeter) |
Temperature Range: |
0 ºC to 50 ºC (Operating) |
Display Update Rate: |
Approximately 3 per second |
Interface: |
Opto-Isolated RS232 Optional |
Max Internal Voltage: |
4.8 VDC - 4 ea. 1.2V Ni-CADS |
Batteries: |
4-AA Alkaline |
Size: |
mm/8" D x mm/7" W x mm/2.5" H |
Weight: |
2.7 KG/6lbs NET 3.7 KG/8 lbs shipping |